22645 83rd Ave, S Building D
Kent , WA 98032
206-772-7502

Local Reviews
for kirkland, wa

Rated 5.0 out of 5 stars based on 6 customer reviews

Marlon is Great, friendly and know his thing

the service is Great,from Kathy to the service crew to materials procurement and the installation are awesome. project got done in time.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

prefect

prefect

  • Overall Experience
  • Quality
  • Price
  • Convenience

Maintenance supervisor

He was very knowledgable and walked me through what I need to know

  • Overall Experience
  • Quality
  • Price
  • Convenience

Fast, Efficient and Friendly

Working with NW Fire is always effortless and enjoyable. The techs know their stuff and are courteous and professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Efficient and Effective!

Allec was out to our community in Kirkland today and was so helpful in testing our backflow and was nice enough to provide details to the city on our behalf. He was thoughtful to tell me that our fire extinguishers need servicing as well so it's nice to have vendors that care and do the job right the first time!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for kirkland, wa

Thomas M.

Thomas M. Job Checkin

Deficiency Repairs Installed head box Head wrench 6 spare heads


Ryan H.

Ryan H. Job Checkin

Annual Sprinkler, Fire Alarm and Fire Extinguisher Inspections


Ryan H.

Ryan H. Job Checkin

5-year Smoke Detector Sensitivity Testing (7) Smoke Detectors - Replacement of (3) 12V 8Ah Batteries


Ryan H.

Ryan H. Job Checkin

5-year Smoke Detector Sensitivity Testing (7) Smoke Detectors - Replacement of (3) 12V 8Ah Batteries


Allec B.

Allec B. Job Checkin


Caleb K.

Caleb K. Job Checkin


Caleb K.

Caleb K. Job Checkin


Allec B.

Allec B. Job Checkin


Marc P.

Marc P. Job Checkin

Deficiency Repairs Dry SPK-1 / West Side of Bldg by Elevator 4” CSC AG: Missing (1) spare sprinkler head inside spare head box. Ames 2000B 0003842 BFP-2 / W Side of Bldg Inside in Sprinkler Room: Backflow failed testing. #1 & #2 check valve assemblies leaked - Recommend rebuild of #1 & #2 check valve assemblies. 3/4" Ames 2000B Serial #0003842 Located in fire sprinkler riser room on West side of building. Ames 3000SS 3LM0782 BFP-1 / W Side of Bldg Inside in Sprinkler Room: Backflow failed testing #1 & #2 check valve assemblies leaked - Recommend rebuild of #1 & #2 check valve assemblies. 4" Ames 3000SS Serial #3LM0782 Located in fire sprinkler riser room on West side of building. Febco 850 A00677 BFP-3 / in-front BLDG 811. Near sidewalk, L side drvwy if looking at the road.: Backflow preventer assembly does not have 6 inches clearance under assembly. Assembly passed, but was dug up to test - It is covered in tree roots and buried in dirt. Customer will need to make sure there is 6" of


Marc P.

Marc P. Job Checkin

Deficiency Repairs Deficiency for Dry SPK-1 / West Side of Bldg by Elevator 4” CSC AG: Missing Sprinkler Head inside spare head box Deficiency for Ames 3000SS 3LM0782 BFP-1 / W Side of Bldg Inside in Sprinkler Room: Check Valve 1 & 2 plummets straight to 0 when testing Deficiency for Ames 2000B 0003842 BFP-2 / W Side of Bldg Inside in Sprinkler Room: Check Valve 1 & 2 Plummets to zero Suggested for Febco 850 A00677 BFP-3 / in-front BLDG 811. Near sidewalk, L side drvwy if looking at the road.: Backflow preventer assembly does not have 6 inches clearance under assembly. Assembly passed, but was dug up to test. it is covered in tree roots and buried in dirt.


Zeke  D.

Zeke D. Job Checkin

Annual Fire Sprinkler,


Andy D.

Andy D. Job Checkin


Colby F.

Colby F. Job Checkin


Andy D.

Andy D. Job Checkin


Marc P.

Marc P. Job Checkin

) FDC check valve located at riser. Febco 805Y 149981 BFP-3 / 15' NW of Main Water Meter in Irrigation Box: Backflow failed testing. #1 check valve assembly failed - Recommend full rebuild kit for #1 & 32 check valve assemblies. Backflow is under water due to rain. 3/4" Febco 805Y Serial #149981 Located 15' NW of main water meter in irrigation box. Recommend scheduling this in warmer/dryer weather - won’t be able to repair when it’s under water. Dry SPK-1 Sprinkler room in Garage: Dry sprinkler system due for 3 year full trip. To be scheduled in Spring.