Angel T.

Angel T. Job Checkin

Installed mini split system in garage. Ran new line set outside and pressure tested it. Used Microleak detector for a leak check. Upon verification, we pulled a vacuum to evacuate the line set and released the refrigerant. Mounted condenser to a bracket on the exterior wall and installed the line set cover. Ran drain underneath bracket and verified system operation and drain operation.


Ethan D.

Ethan D. Job Checkin

Replaced the upstairs air handler. Reinstalled supply and return plenums and sealed with mastic air lock. Rebuilt primary and secondary drain lines. Installed SS2 and SS3 safety float switches. Cleared and verified drain operation. Pressure tested and pulled a vacuum on the line set. Verified system operation and weighed in charge based on line set length.


Ethan D.

Ethan D. Job Checkin

Installed new 2.5-ton Carrier gas system. Installed new Honeywell thermostat. Installed new plywood overlay. Installed new filter base. Installed new gas shut off valve. Rebuilt and insulated condensate drain line. Added SS2 safety float switch. Cleared and treated drain and verified operation. Transitioned to supply plenum and sealed with mastic air lock. Installed new filter dryer, pressure tested with dry nitrogen and pulled a vacuum on the copper line set. Replaced disconnect and whip at outdoor system. Verified system is to factory spec. System is working properly at time of departure.


George T.

George T. Job Checkin

Found system not operational due to safety feature tripped. A breach in the heat exchanger is suspected due to common failures with furnace safeties. I also found a large buildup of rust in the system. Client would like to speak to our Comfort Consultant regarding replacement options.


George T.

George T. Job Checkin

Performed maintenance on two gas systems. A complimentary clean was performed in both interior cabinets and systems are now operational.


Doug G.

Doug G. Job Checkin

Installed new Mitsubishi mini split. Ran line-set and drain but need to return and finish copper. Will return next week to complete work.


Ryan P.

Ryan P. Job Checkin