Jason D.

Jason D. Job Checkin

Performed service diagnostic and found a refrigerant leak at the evaporator coil. I gave the customer options, and they chose to have the coil replaced. Replaced indoor evaporator coil. Reattached drain and insulated it. Installed new inline filter dryer, pressure tested with dry nitrogen and pulled a vacuum on copper line set. Charged system with new R-410A refrigerant. System is working properly at this time.


Elijah D.

Elijah D. Job Checkin

Found system low on refrigerant charge. Inspected all systems and recharged to manufacture’s specifications. Verified everything is working at this time.


Leonard P.

Leonard P. Job Checkin

Performed maintenance on the AC system. I cleared the drain line, cleaned condensing coil, checked pressures and all electrical connections. Found that the condenser capacitor was out of manufacturer’s specifications. Also found that the fan motor showed signs of overheating. Gave customer options to replace the capacitor, fan motor and add surge protection. Customer chose to replace capacitor. I completed the repair and system is operational.


Jason D.

Jason D. Job Checkin

After performing the diagnostic I found a bad starter. After replacing the starter and getting the system back up and running, I found that it was completely empty on refrigerant. Performed leak search and found a leak in the condenser coil. I presented the client with her options, and she chose to have the condenser replaced. Replaced 3-ton condenser. Replaced inline filter dryer. Pressure tested with dry nitrogen. Pulled a deep vacuum on copper line set. Charged system to factory specs. System is working properly at time of departure.


Max  B.

Max B. Job Checkin

Performed the AC tune-up and everything is working at this time.


Max  B.

Max B. Job Checkin

After performing the diagnostic, I found that the defrost control board has failed and is not sending the correct voltage through it. I also found that the starter has failed and is stuck closed. I presented the client with his options, and he chose to have it all replaced. We are ordering the control board and will return to install once it arrives. Trip 2 - Replaced the condenser control board, starter and added 2.5 lbs of R-410A refrigerant to the system. After performing the repairs everything is working at this time. I did find that the condenser fan motor is running hotter than it's supposed to and the secondary drain pan needs to be replaced. I presented my findings to the client.


Matt F.

Matt F. Job Checkin

Performed AC cool check. Checked electrical, mechanical, safety, and performance of the system. Condenser fan motor showed signs of overheating and had leaked internal lubricant. Drain line cleared and treated and condenser coil cleaned. Options to replace condenser fan motor and install surge protection system were presented to customer and customer chose to move forward with repairs. Repairs were completed and system tested. Electrical disconnect confirmed in and on. System was running at time of departure.


Max  B.

Max B. Job Checkin

After performing the diagnostic, I cycled the system which reset the furnace control board causing the system to work properly. I presented options to do a complete inspection of the system but since the customer is on maintenance, she chose not to have me complete the inspection. I also highly recommended the installation of a carbon monoxide detector inside the house, but she said she would do it herself.


Ethan D.

Ethan D. Job Checkin

Checked the American Standard system in attic. Verified electric heating and cleared drain with CO2. Washed out condenser and checked voltage enhancement system.


Max  B.

Max B. Job Checkin

Performed the heater tune-up on the American Standard heat pump system. Everything is coming on and working to industry standards at this time.

Performed the heater tune-up on the American Standard heat pump system. Everything is coming on and working to industry standards at this time.

Max  B.

Max B. Job Checkin

Performed the heater tune-up and everything is working at this time. While performing the inspection I did find the voltage enhancer to be weak and undervalued going to the blower motor; rated at 7.5 but reading 6.1. I gave the customer her options and she chose to have it replaced at the platinum level at this time.


Max  B.

Max B. Job Checkin

Performed the heater tune-up and everything is working at this time. While performing the inspection I did find the voltage enhancer to the blower motor to be weak and undervalued. Rated at 7.5 but only reading 4.1. I gave the customer her options and she chose to have it replaced at the bronze level at this time. After making the bronze level repair on the indoor voltage enhancer everything is coming on and working at this time.


Chase R.

Chase R. Job Checkin

Found the system low on R-22 refrigerant. Conducted basic leak search and could not find a leak at this time. Recharged the system and it is now cooling at this time.


Max  B.

Max B. Job Checkin

When I arrived, I found a fault in the voltage enhancement system. I gave the customer his options and he chose a basic option repair. The system is cooling after completion of service.


Max  B.

Max B. Job Checkin

Performed the AC tune-up and everything is working at this time. While performing the inspection I did find the voltage enhancer to be weak and undervalued. I gave the customer his options and he chose to hold off at this time.