Performed annual heating maintenance on a 2023 Coleman Downflow furnace. Replaced 2) 16x20 filters located in fau. Cleaned out burners furnace. Verified heating sequence of operation is working properly according to manufacturer specifications. Checked flue pipes were secure. Checked and detected zero carbon monoxide. Checked temperature rise. Everything checked out in range. Emerson thermostat checked out operational. System is working in heating at this time of service.
Installed American Standard 3 ton Condenser and Coleman Down-flow Furnace ADP Evaporaror Coil. Job completed. However we could not convert the unit from natural gas to propane gas because we did not have the right size Allen key, but I told Bryan and he will bring the Allen key and convert to propane gas.