Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Furnace):** * Located in the attic, servicing the whole home. * Replaced the pleated 2-6" air filter (16x25). * Indoor coil condition is fair and clean. **Outdoor Unit (Straight Cool):** * Located on the side of the house. * Outdoor coil condition is fair. * Unable to read the data plate. **Electrical Components:** * Tested and confirmed proper operation of: Inducer Draft Motor, Blower Motor, Condenser Fan Motor, Compressor, Blower Run Capacitor, Fan Run Capacitor, Compressor Run Capacitor, Contactor, Electrical Wiring, and Furnace Control Board. **System Components (Good Condition):** * Inspected and confirmed proper operation of: Blower Wheel, Burners, Exhaust Flue, Heat Exchanger, Primary Drain Pan, and Secured Electrical Wires. **System Readings & Adjustments:** * Carbon Monoxide levels: 0.00 PPM. * Return Air Temperature: 67.0 Degrees Fahrenheit. *