Have any feedback for us? We'd love to hear it! Call us at (760) 910-7600 and let us know how we are doing.
Executed a heating maintenance on an 80k BTU 2006 York natural gas furnace, located in the attic - - laundry room access. Equipment executed sequence of operation in heating. Cleaned burner compartment of spiderwebs, dirt and debris. Cleared condensate drain line. Client replaced filter. Temperature rise 40°. No carbon monoxide was detected in the home. Blower capacitor – good. Blower motor amp draw measured within manufacture specifications. Static pressure measurements recorded and documented in photos. System is heating the home at the time of maintenance.