123 S Date Ave
Jenks, OK 74037
918-299-1955

Our Top Cities


Job Locations
for broken arrow, ok


Map of Broken Arrow OK
Chris V.

Chris V.


Job Checkin

For this job, Technician performed a two system PSO tune up on a 15 year old Goodman system and a 13 year old Goodman system. Technician checked all safety devices and components that are in use during the A/C season. Technician found the Downstairs A/Cs compressor is pulling over the max amp draw on its last leg, The Contactor switch is making a loud buzzing noise and looks pretty rough, as well as The refrigerant levels show a restricted indoor coil. The Upstairs system is over charged with R-22, all components are within ranges. Both systems are running at this time. The Downstairs system is a worry being summer time is here. Customer would like for Tim to give him a call to go over options.