Upon arrival I inspected meter and saw that meter was indicating that there was a leak at about .15 gallons per minute. Isolated system between irrigation and home and was able to determine that there where not water leaks on system feeding the home but there was a leak on irrigation side. Inspected irrigation valves and saw several different leaks on irrigation valves in the backyard. The valve second to the left was leaking and had a steady drip coming from it. And there where two other valves that has visible water leaking down the back side of the pvc with moss growing on them. There was also a slight leak on one of the irrigation valve in the from where the 3/4” pvc threaded into the valve. I believe that these leaks are contributing to the meter constantly spinning. Once I shut valve off feeding the irrigation system the meter stopped spinning indicating that the leak is isolated to the irrigation feed. Once these issues are address I recommend inspection of meter to make sure th