Performed camera inspection of sewer main via cleanout on exterior wall of kitchen sink. While performing inspection I found several offsets and root intrusions that need to be addressed. First issue was right inside of home by front door and had about a 25’ section with several root intrusions that I recommend replacing via pipe bursting method. After this section customer had a long stretch of ABS drain piping that was in good condition but had one last root intrusion where the ABS and clay pipe met out close to the street at about 6’ deep. Was unable to get camera past this section due to the length of the run and amount of turns. Recommend digging up and performing spot repair on this section. All spots needed that will need to be dug up to perform repairs and pipe bursting are marked and labeled holes 1-4 with tape as well as the depths. Hole 1 is located in the home and is the 3” cast iron to 4” clay transition and has a root intrusion. I recommend pipe bursting from hole 1-3 a