Arrived at customers to change compressor. On arrival customer show me outside to condenser. Turn off power to system. Reclaimed remaining refrigerant. Removed old compressor. Installed new compressor. Braised and fixed compressor into system. Pressure tested unit over 400 psi and pressure held. Vacuumed unit under 500 µm. Added factory weight and started off the system. Added Freon to get correct. Charge and readings. Unit is now properly cooling. Checked in with customer and customer is happy with work performed. Collected payment and signatures and left. Thank you for choosing total air