3100 39th Ave North
St. Petersburg, FL 33714
727-822-7700

Local Reviews
for tierra verde, fl

Rated 4.8 out of 5 stars based on 10 customer reviews

Outstanding Service!

Casey Spangler arrived at 3:30 PM Friday afternoon and worked extremely hard for 2-hours to get our primary air conditioner back online. Casey is outstanding!!!!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding service!

Casey arrived very quickly for a Sunday evening emergency call. Casey was very personable, knowledgeable and helpful. He determined the compressor fan motor failed and hopefully a replacement will be available. Thanks

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding HVAC Service

Out HVAC systems annual service took place today from Total Air. Our technician, Arionna Lunceford, did an outstanding job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Total Air/Wade is awesome!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Back up and running!

Tom arrived, very quickly diagnosed and resolved the problem. Tom is a 10 on a 1-5 scale. The challenge was the error message indicated that a temperature sensor had failed and reality was the outside unit was without power. The other opportunity was called yesterday at 10:45 AM, was supposed to receive a callback that did not happen, called 3 hours later and the best they could do was a 12 PM appointment today.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Total Air

Very good work, on time and at the quoted price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing experience

I can not say enough positive things about my experience. The Price . Quality of information and service were amazing. Thank you


Response from Total Air, Inc.:

We are incredibly grateful that you took the time out to leave us a 5-Star review.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service

Raiko did an outstanding job checking out our (2) HVAC systems and was extremely knowledgeable and personable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service- 0n time delivery

  • Overall Experience
  • Quality
  • Price
  • Convenience

Two mini splits and two variable speed units

Total Air have been excellent from Rigo’s first visit to all contact with the office and guys on site

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for tierra verde, fl

Wade H.

Wade H. Job Checkin

Pure Air Serial Numbers 0120123 - NLT218 - 9880 0011024 - NLT218 - 1134 Notes: returned to reseal plenum and immediate ducts for the upstairs unit. Once sealed I installed a pure air x in both air handler cabinets. Wiped down biogrowth inside cabinets and supply vents. 2 bedroom vents have some rust / biogrowth that is hard to get between the fins. Summary: both blower wheel assembly’s have some drywall dust. Once projects are completed I suggest a pull and clean on each unit. Performed a clean in place on both evaporator coils. Cleared and flushed both drain lines. Gathered delta t. Left both systems in the off position. Collected signatures and payment. This job has been completed. Thank you for choosing Total Air!


Wade H.

Wade H. Job Checkin

Notes: arrived for two system tuneup. Main floor unit condenser was not working. Found capacitor was bad and mushroom. Once replaced. The unit started right up. Performed full system on each unit. Waived today’s fee and this will be one of two maintenances for the year. Summary: the attic air handler has air leaks in the attic off the supply, and return Plenum and immediate ducts. I suggest properly ceiling to help with efficiency. Inside the cabinet has biological growth. It is also on the supply vents and outside the Plenum. A UVC germicidal will keep the cabinet clean and produce better. Indoor air quality. The downstairs safety float switch was wired wrong/cut. Customer agreed to replace switch and it is properly working now. Both systems are cooling and heating well at this time. I collected signatures and payment. This job has been completed. Thank you for choosing Total Air!


Tony P.

Tony P. Job Checkin

Perform a leak search on System A which is the main system for the house. Added 2 pounds of refrigerant to increase pressures and performed leak search on the indoor coil was giving a few readings on high side with the electronic leak detector but couldn’t pin point it with the low side, checked outside coil and components and didn’t get any readings, noticed coil deteriorating and accumulator is rusting at the bottom, went in the attic and checked the line set with the leak detector all the way to the corner of the house and didn’t get any readings, quoted to add Leak seal and 3 pounds of refrigerant as a band aid and hope it holds, did not charge for the 2 pounds of refrigerant I put in initially to perform the leak search, System is topped off at this time, if it continues to leak than due to conditions of the system rusting and having problems homeowner might move forward with a new system. We could do an isolation test and pressurize the system with nitrogen but that would cost mo


Wade H.

Wade H. Job Checkin

Preventative maintenance inspections. Checked blower motor operation and inspected evaporator coil condition. Checked safety float switch and inspected drain line. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Checked refrigerant levels and check test start up components. Unit is cooling well and drains properly. Condenser unit has good safety surge protector on condenser unit. Air handler unit is good uvc germicidal uvc light and is luminous. Installed new nest thermostat and set up app and WiFi. Customer has finished the update and nest thermostat is working properly. Thank you for choosing total air


Arionna L.

Arionna L. Job Checkin

I return to replace the thermostat wire, running to both systems with shielded communication wiring.


Wade H.

Wade H. Job Checkin

System be inside unit and outside unit was not running. Four codes were showing a communication error with the indoor blower motor and thermostat. I cycled power at the electrical panel to reset the unit. The unit restarted. Went back through the fault codes and showed that the history of default codes was communication error. Both system and system B currently has 18 gauge six wire install throughout with multiple spices. It is my recommendation to replace those wires with communicating wires as recommended by the manufacture.


Wade H.

Wade H. Job Checkin

I return to replace outdoor defrost fort. Picture has been uploaded to service titan showing that one of the two misters on the board burnt out which caused the short in the board.


Wade H.

Wade H. Job Checkin

The Schrader valve on the suction line was leaking refrigerant due to previous gauges being over tighten and damaging the valve. I replace the valve and refilled the system with 4 pounds of refrigerant. I let the system run for over an hour and the pressure is held.


Wade H.

Wade H. Job Checkin

After reinstalling the parts. I rediagnosed the original problem of low voltage short. I found a section of wire exiting the wall of the house next to the line set had a splice and portion of the wire was corroded and exposising bare wire. I stripped back the wire to expose clean wire and respliced a new wire running to condenser. System is running and has been running for 45 mins without interruption.


Wade H.

Wade H. Job Checkin

Replace UV Bulbs Upon arrival to the multi scheduled system maintenance, I was shown to the a/hs in the garage and c/us on the side of the home. I pulled off the panel door to inspect all electrical components connections, collect amp draw/voltage readings off electrical equipment, and check the unit for cleanliness. I inspected the evaporator coil and blower fan and both are free of biological growth and debris build up. The d/t temperature was within normal range for each system (20°). All electrical components were secure and within factory range. I tested the float safety switch and confirmed it is engaged when needed for each system. I then vacuumed the condensate drain line to remove and blockage or debris. I ensured this was draining properly. The c/u system refrigerant charge is within normal range for both systems and all electrical components are secure. I collected amp draw/voltage readings and the capacitor is low on both c/u’s Immediate needs: I strongly suggest repl


Tom L.

Tom L. Job Checkin

Warranty Air Handler Control Board. Returned to customer home to perform quoted work. Installed a new AH board,


Tom L.

Tom L. Job Checkin

Upon arrival customer told me AC was not run. Found low-voltage short with a contactor that was bad replace low-voltage short and contactor. after doing those repairs there’s still a short somewhere in a low-voltage wire cannot get it up and running no one lives at the home please call in the morning to do a schedule call back up. Prefer to have two people to chase wire and find a low-voltage short


Wade H.

Wade H. Job Checkin

Customer concerned about unit not cooling properly. Checked blower motor operation and inspected safety float switch and inspected drain line. Customer has approved for drain line cleaning. Cleaned vacuumed drain pan and drain line. Flushed drain line with water and primed drain line. Checked thermostat calibration and filter location. Customer has replaced filter. Unit is cooling well and drains at this time. Customer would like an estimate for relocate condenser unit to side wall with new aluminum wall rails for the condenser.


Wade H.

Wade H. Job Checkin

Issue that customer is expressing is that system struggles to keep temperature and runs continuously. He is a new homeowner as of the last three years. The home was built in 1989 and the duct is original. All of the R-value in the duct has significantly lowered due to compression, age, and how it was originally hung/connected. After inspecting the supply runs I have found multiple areas where the duct is saturated and a few areas where 70° air is dumping into an attic that is 114°F. I checked the pressures, amp draw, capacitance. The system is functioning and cooling to the best of its ability but it is losing efficiency in the ductwork. At this time my suggestion is to replace all of the duct for both units. Both attic spaces are wide open and easily accessible. Please set up Comfort advisor appointment


Austin H.

Austin H. Job Checkin

Upon arrival to system cleaning I was shown to a mini split head in the guest bedroom that needed a fan coil cleaning. Disassembled indoor unit and pulled out fan wheel and drain pan. Took all parts outside and cleaned with solution and a hose. Let everything sit out to dry and cleaned the evap coil. Reassembled system and cycled the unit in the cooling mode to test proper functions. System is now very clean, with a lot better air flow. System is back operating within range of factory specifications. Left the unit in the cooling mode, spoke to the homeowner about the work completed, collected payment/signatures and left. Job complete. Thank you for choosing Total Air!