Rated 4.7 out of 5 stars based on 7 customer reviews

Total Air/Wade is awesome!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Back up and running!

Tom arrived, very quickly diagnosed and resolved the problem. Tom is a 10 on a 1-5 scale. The challenge was the error message indicated that a temperature sensor had failed and reality was the outside unit was without power. The other opportunity was called yesterday at 10:45 AM, was supposed to receive a callback that did not happen, called 3 hours later and the best they could do was a 12 PM appointment today.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Total Air

Very good work, on time and at the quoted price!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing experience

I can not say enough positive things about my experience. The Price . Quality of information and service were amazing. Thank you

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great customer service

Raiko did an outstanding job checking out our (2) HVAC systems and was extremely knowledgeable and personable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service- 0n time delivery

  • Overall Experience
  • Quality
  • Price
  • Convenience

Two mini splits and two variable speed units

Total Air have been excellent from Rigo’s first visit to all contact with the office and guys on site

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for tierra verde, fl

Jeff B.

Jeff B. Job Checkin

Check duct work Homeowner concerned with a stain on ceiling. Stain is not below either air handler or condensate line. I checked all ductwork in the area. I could not find any wet insulation. There is a damaged duct that would need to be replaced bit it is not the cause of the stain. There is staining on the underside of the roof where a water leak was. I cannot confirm if it is actively leaking as everything is dry. The roof was replaced in the last few years. Home owner will have a roofer come look at it. Office to quote a duct replacement. 1 bag 10in indoor flex duct. 2 6 in collars. Mastic, tape. 1 hour labor. Current duct is not sealed with mastic. Home owner would like a quote on insulation. We will need to set an appointment for me to return on or after November 21st.


Jeff B.

Jeff B. Job Checkin

No cool. Outdoor unit not running on main floor system. Found bad capacitor and attempted to replace. After installing capacitor, found system tripping breaker due to a short to ground fault. Compressor is failed and would need to replaced for system to run. Due to condition of the system and high cost of repair, the homeowner would like a quote to replace. Home owner will be available after 12pm noon for a call to set an appointment. He would like the comfort advisor to come by after 5 pm if possible. Home owner signed up for maintenance program today. 2 systems. System is down until replaced or repaired.


Wade H.

Wade H. Job Checkin

Customer has provided items. Hurricane relief Customer concerned about unit not cooling properly. Customer reset breaker that has tripped off. Checked thermostat calibration and filter location. Checked outside condenser unit and located condenser fan motor is not working. Checked capacitor and line voltage wiring connections. Recommend new Taps membership to reduce cost for parts and services. Recommend heat pump unit replacement due to aged equipment and shows signs of rust and failure. Require repair is a universal condenser fan motor replacement. Customer has approved for motor replacement Replace condenser fan motor and checked unit operation. Unit is cooling well and drains at this time. Gave customer 50$ coupon Gave customer new Taps membership folder


Jon C.

Jon C. Job Checkin

Customer concerned thermostat not not working correctly. Located bad wiring in thermostat. Fixed wiring and check thermostat calibration. Unit is cooling well and drains at this time. Customer is satisfied with service. Offer to install customer supply thermostat. Customer has declined at this time.


Wade H.

Wade H. Job Checkin

Customers condensate line is completely clogged. Needs entirely new. Charged for attempted flush today. Customer would like call ASAP confirming soonest possible appointment. 30 feet of PVC, 4 90s, 2 unions, 1 cuplink


Wade H.

Wade H. Job Checkin

Arrived at customer's house for no cool. On arrival customer showed me to air handler unit. Condensate pipe had come loose from unit. Gave customer price to repair and customers agreed. Installed new male PVC fitting fitting and new section of condensate line. Sucked out drain line. Unit now running. Giving acceptable delta T. Told customers I am not extremely confident in female futting on drain pan.. appears to have been cross threaded in past. Collected payment and signature for today's work and left. Customers happy.


Casey K.

Casey K. Job Checkin

Install 2 ton 15 Seer mini split system air handler and Brand New hanging mounts modified supply and return plenums with mechanical fasteners and heat shield flush copper flush drain built and installed attic plywood decking for serviceability condenser on padlock pad fasten pads together and then fasten to the whole padlock pad to concrete system held pressure over 400 psi G and vacuum below 500 µm rewired existing nest thermostat changed breakers accordingly hung permit started system up and charged to factory spec walked customer through How to operate their brand new HVAC system customer paid balance in full via credit card job is complete and inspection ready


Wade H.

Wade H. Job Checkin

Arrived at customer's house for system inspection. On arrival customer showed me to air handler unit and laundry room. Check inside of unit and saw UV light that was not working. Toggled the breaker and the light would turn on but not stay emitted. Got light information in case customer would like to search for bulb. Suggested he go with our pure air. Row estimate. Next month upstairs to York unit and checked out that air handler. That air handler had bio growth and 2 UV lights that were not working. Next went downstairs to condenser's. 1st checked the York unit and your unit was getting cool but not Keeping up well enough. Customer also had complaints about unit. Suggested he get consultation and customer agreed. Next I checked the Bryant unit and the Bryant unit was fine. Unit was keeping up. All pressures and readings were of acceptable range. Talked with customer about options for installation as far as add as Adam's. Waited for Kyle to arrive. Signed customers backup with annua


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Fan motor replacement Replaced fan motor and air handler. Started unit and unit now running fine. Collected payment and signature from customer. Customer happy.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

System not cooling. I found the cause of this to be a bad blower fan motor in the evaporator. We will need to call in the morning to check warranty and order the motor for this unit. We will check pressures and system operation after repair has been made. All customer with price and timeframe of when we can get it.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Replaced defrost board in Rheem condenser unit. Changed out coil temp and ambient temp sensors provided with the board and recommended by manufacturer. Rewired common on the contactor back to the board (undo bypass). Home owner decided to change out weak capacitor while I was here today. Installed t200 capacitor with 5 year warranty. Cycled system to insure proper operation. Home owner paid for services today with a single check (#9797) for total balance. System operating properly at this time.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

System not cooling. I found there to be two issues causing this. The first was that the contactor had failed so even when it got 24v it wouldn’t pull in. The second issue is that the control board has a short on the common I have unhooked common and bypassed that part of the board allowing the unit to run for now but we will need to change this board out. The model and serial number is worn off from the unit so we have no way to order it now the customer said he thinks he has it somewhere in his paperwork and will find it and send it to us. The capacitor is also weak and needs to be replaced. The air handler has growth formed in it mainly on the blower wheel it should be cleaned. I did recommend considering replacement, for now we have decided to move forward with repairs. We will need to provide an estimate to change the capacitor as well as the control board on the condenser.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Upon arrival customer told me that the inside was working but the condenser will not kick on. Went to the condenser and checked the capacitor and it is good and also the contactor. Had 24 volts going to the board but not leaving to go to the contactor. Bypass the board so he customer has ac. Will need to order a defrost board.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

On arrival found system low on refrigerant. Found a large amount of oil in vapor li e armor flex at air Handler. Leak is very small and could not pinpoint which weld is leaking. Home owner opted to refill today and leak search and/or repair in the future. Home owner requested I return for leak search. Left system cooling but still has small leak in refrigerant cycle.


matt@totalairinc.net

matt@totalairinc.net Job Checkin

Upon arrival customer told me the ac was not working. The thermostat said outside sensor not reading. I had no power going to the condenser. Customer just had a generator installed on Thursday. The problem has something to do with the generator and the extra box they put on the disconnect.