Wade H.

Wade H. Job Checkin

Miscellaneous - house is up for sale, rodents have eaten some of the duck work want a quote to fix. Aware of the 79.95 service call Checked ductwork connections and inspected equipment cabinet. The attic has flexable ductwork that has been damaged and broken. All flexable ductwork needs to be replaced. I have found the flexable duct old and smashed, air blowing in the attic. 6 flexable runs will need to be replaced. Needs the 3bags of 7” flexable ductwork replaced and 1 bag 5” flexable ductwork to the bathroom. Have mentioned the attic insulation is very poor and needs to be insulated. Customer is interested to have quotes for attic insulation after the flexable duct replacement. (No collars needed) 3 bags 7” flexable duct 1 bag 5” flexable duct Mastic and brush Hanging cloth strap 3 hrs Customer is interested of quote for blown in attic insulation.


Austin H.

Austin H. Job Checkin

Upon arrival to Mini split head cleaning I was shown to mini split head in upstairs bedroom. Took apart mini split head and pulled out the fan and drain pan. Took fan wheel outside and cleaned with cleaner and a hose. Cleaned coil with solution and foaming cleaner and wiped down entirety of the unit. Reinstalled fan wheel and put unit back together and ran unit in cooling modes. This unit is running much more efficiently and pushing way more air throughout living space than it was before. Spoke with homeowner and is happy with work performed. Collected payment/signatures and left. Job complete.


Jon C.

Jon C. Job Checkin

Arrived at customer's house for condenser nonstop running. On arrival customer showed me to condenser. Thermostat inside was off customer turned breaker on and condenser turned on. Tested and confirmed there was no 24 V call from the thermostat. Moved the column that controlled the individual contacts and they released. The plastic side in the middle is getting stuck. The beads are not welded closed. No pitting is seen. Explained this to customer and told her she needed a new contact her. Customer agreed. Installed new contact or. Started off unit about 5 Times. Unit shut down when it was supposed to with new contactor. Confirmed with customer and Customer is pleased with work performed. Pointed out to customer that they did not have A surge protector on the system. Explained the benefits of our surge protector. Collected payment and signatures and left. Customer happy.


Casey S.

Casey S. Job Checkin

Performed preventative maintenance. Took amperage of indoor blower motor and electric heat strip. Calibrated and tested thermostat. Inspected and tightened electrical. Replaced filter customer provided. Cycled heating and cooling. Took temperature difference. Cleared drain pan and drain line. Located condenser on side of house. Inspected and tightened all electrical. Checked capacitor. Checked refrigerant levels. Took amperage of compressor and outdoor motor. Cleared debris from condenser housing. Rinsed condenser coil. System operating to factory standard. Recommend blower wheel cleaning. Spoke to customer and showed the biological growth, customer opted with blower wheel cleaning.


Austin H.

Austin H. Job Checkin

Upon arrival to scheduled maintenance I was shown to an A/H unit in a closet. Took off panel door to inspect all electrical components amp draw/voltage readings as well as check the evap coil. Evaporator coil was clean and readings of electrical equipment were within range of factory specs, except for the run capacitor that powers the fan motor. Capacitor was running low and below rating, I suggested to homeowner that we go ahead with replacing to ensure she wouldn’t be without cool air down the road. Installed new turbo 200 mini. Went to outdoor C/U to check Freon levels as well as inspect and collect readings of all electrical components connections. This unit is equipped with a new turbo 200 capacitor and contactor that are fully operational at this time. Freon levels were on point. Cleared drain with vacuum and followed with solution to ensure drainline was clear and properly draining with unit in operation. Overall this unit is operating very well, spoke with homeowner


Jon C.

Jon C. Job Checkin

Arrived at customer's house for system inspection. On arrival customer showed me to airhandler system. Under evaporator coil was clean. Inside air handler cabinet was infected with bio growth. Pointed out to customer and suggested and IAQ.Turned on unit and unit was producing proper Delta T. Went outside to condenser and open electric cabinet. Found capacitor below acceptable range. Pointed it out to customer and suggested we change. Customer agreed. Changed out capacitor and unit now runs fine. Vacuumed out drain line. Unit is currently not equipped with a surge protector. Pointed it out to customer and explain benefits of surge protector. Created estimate. Collected payment and signatures from customer and left. Customer happy.


Jon C.

Jon C. Job Checkin

Arrived at customer's house for system inspection. On arrival home owner showed me to air handler unit. Opened up cabinet and saw bio growth. Unit is equipped with a surface UV light. Bulb is past change date though. Pointed out to customer and suggested they get bulb changed. Customer is waiting for a loan to come within the next few weeks. Will call us to get bulb. Also informed customer of upgraded UV light. Left literature with customer and customer will consider upgrading with loan money. Also informed customer of our financing options. Unit was producing proper Delta T. Next went out to condenser unit and opened electric cabinet. Tested all components. Contactor sending proper voltage. Capacitor within acceptable range. Vacuumed out drain line. Unit is currently not equipped with a surge protector. Informed customer of this and suggested he get 1. Created estimate. informed customers that their plan was running out by the end of this month. Suggested they signed up with plan. Cu


Tom L.

Tom L. Job Checkin

Upon arrival customer showed me an ac unit in the laundry room that needed tuned up. The evap coil is clean. Cleared condensate with shop vac and water. The Uv Light is working good. The thermostat was programmed to replace the bulb every 6 months. I reprogrammed to be replaced every 24 month. Checked all amps and volts. Went to the condenser checked all amps and volts.


Wade H.

Wade H. Job Checkin

Performed preventative maintenance tune up. Checked blower motor operation and inspected evaporator coil condition. Checked safety float switch and inspected drain line. Cleaned vacuumed drain pan and drain line. Checked thermostat calibration and inspected filter location. Checked refrigerant levels and check test start up components. Cleaned debris from condenser and rinse compressor deck. Unit is cooling well and drains at this time. Customer declined membership at this time. Customer has coupon for maintenance tune up.


Wade H.

Wade H. Job Checkin

EAC Media pad replacement.


Josh W.

Josh W. Job Checkin

Tear out existing air handler replace air handler on new stand hook up existing plenum high voltage low voltage drain line new thermostat new heat shield and mechanical fasteners tear out condenser replace padlock pad new condenser tired existing copper high voltage low voltage drain line nitrogen test 400 PSI vacuum down to 500 microns start up everything's working in perfect condition added 3 lb of 410A freon


Wade H.

Wade H. Job Checkin

Upon arrival customer told me the ac was not working. The indoor fan was on and also the condenser was running. Put my gauges on and it was almost empty of all freon. Customer had another company add freon on 7/25/22 and another company add freon on 8/23/22. We can not add any more freon. Comfort advisor Coming out to give quote.


Wade H.

Wade H. Job Checkin

Customer had a plastic bag sucked into the opening on his return. Bag was stuck on stuck on evaporator coil. Remove bag and start it up unit. Unit started fine. Check in with customer and customer was happy. Unit now cooling properly. Collected payment and signature and left.


Wade H.

Wade H. Job Checkin

Upon arrival customer told me the ac was not running outside. Found a bad 35/5 capacitor which made the unit go in lock out mode replace with a turbo 200. Restored ac to home


Wade H.

Wade H. Job Checkin

Customer concerned about unit leaking water from unit plenum. Check blower motor operation and inspected evaporator coil condition. Checked drain pan and drain line, located clogged drain line. Cleaned vacuumed drain pan and drain line. Treat with solvent and prime drain line. Suggest new drain line in garage under cabinets to and thru front exterior wall to front planter. Pvc Drain pipe and hole thru concrete.