Replaced circuit board, repacked acid neut tank and checked all regen cycles. Found source of leak: clack ws1 acid neutralizer valve drains to slop sink which is backing up with dirt, was told to contact a plumber. No leaks. All good. pH: 7.2 Hardness: N/A Kinetico softener unknown.
Customer complaining of leak arrived at house saw about an inch of water around the pump and outside of the doorway to the pump. Turn on ran water twice so nothing leaking. Explain to customer may be coming from floor drain or something else. pH was 6.5 recommended getting his neutralizer working no power to control board Wants us to order board and get the neutralizer back working need to set up another appointment
Install a 48,000 grain metered Clack water softener with a WS1 filter valve, bypass valves and a new brine tank. Install a 2.5 cubic foot whole house Centaur carbon filtration system with a WS1 valve and bypass valves Clack products are warrantied for five years and our workmanship is warrantied for 90 days.
Locate and excavate wellhead. Excavate and raise well casing with welded 6" steel casing. Install a new pitless adapter and 2 piece well cap. Install 115V 1/2 HP submersible pump with new 160 PSI well pipe and12/2 flat jacket well wire. Install a new lateral line wire 12/3 twisted and estimated at 50'. Estimated pump set depth is 120'. Install a new 33 gallon well tank with fittings.
Replace existing jet pump, foot valve and well tank. The tank will be manufactured by Well Rite and the jet pump by Goulds or of similar quality depending on in-stock availability at the time of order, all fittings to complete the work will be provided. Note that the fittings line item may vary and is subject to the actual fittings used to complete the work. An itemized invoice will be provided.
Installing a nutrlizer in Ewing NJ
Whole house carbon filtration