Changed sediment filter, Educated and showed client how to change filter, Checked all cycles, No leaks, all good. *water currently hard no salt in tank. Filled with provided salt & set to regen tonight.* Hardness:15 Ph: 7.9
Customers bulb sizes ATS 1805, PH is at 7.5 , TDS is 104, hardness is five. Change her 2 x 10 string filter with one of her filters.
Provide a service call review of the existing equipment and make recommendations for serviceability and reliability of the existing equipment. Perform a basic water analysis
- Raise steel well casing by welding a coupling and 18" extension on the existing. We are assuming the well head is flush to the ground and that excavation is not required. - Install a new well cap, Bucks County Health department approved and vermin proof. - Chlorinate the well. - Install an 8 GPM UV light system and we are assuming there is an existing pre-filter. - Install a sample port post UV for final water testing (bacteria coliform and E.coli)
They have a UV light 2 x 10 filter softener, neutralizer everything CG working new 203 tank only about a year or two old all the sediment is stopped coming into the house could be something the last service guy put in the pipes to clean them they said
Install a water softener and a 2 x 10 filter