Today I arrived on site and performed a winter time maintenance on your HVAC equipment. **Indoor Unit (Air Handler):** * Located in the closet, servicing the downstairs area. * Checked the pleated 20x20x4 filter; it's in good condition. * Confirmed the indoor coil is clean and in good condition and brush cleaned today. **Outdoor Unit (Heat Pump):** * Located on the side of the house. * Verified the outdoor coil is clean and in good condition and cleaned today. **Electrical Components:** * Tested and confirmed proper operation of the blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring, all within manufacturer's specifications. **System Components:** * Inspected and confirmed the blower wheel, primary drain pan, and electrical wires are secured and in good working condition. **Condensate Drain System:** * Cleared the drain line. * Cleaned out the primary pan. * Tested th