We're way out away from civilization, but these folks managed to help us out in a breakdown, then their maintenance is great.
Justin was very polite and professional -- he found and fixed the problem in no time and suggested some preventive care --
Lee Costa gained our trust his first visit. He still has it. Jessie seems to be a very sharp, competent and very customer oriented technician. We were very impressed. She should be a great asset to your team.
Today, I arrived on site to perform winter maintenance on the HVAC equipment. Overall Equipment Condition: * Good condition noted for the system. Indoor Unit Details: * Located in the closet as an air handler. * Services the whole home. * Filtration system is washable; checked and washed today. * Filter size is 20x20. Indoor Coil Condition: * Fair condition and clean. Outdoor Unit Details: * Located on the side of the house as a heat pump. * Outdoor coil is in good condition and was cleaned today. Electrical Components: * Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Contactor, and Defrost Control Board were tested and are working properly within manufacturer specs. * No electrical components were found to be malfunctioning. System Inspection: * Blower Wheel, Electrical Wires, and Primary Drain Pan are in good condition. * No components were found in poor condition. Temperature Readings: * Retur
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Closet - Type: Air Handler - Picture: [Provide picture] Area Unit Services: - Whole house Filtration: - Washable - Filter washed today Filter: - Size: 20x20x5 - Picture: [Provide picture] Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Provide picture] Condition of Outdoor Coil: - Good - Clean Tested and inspected electrical components: - Blower Motor - Condenser Fan Motor - Compressor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Electrical Wiring Inspected components in good condition and working properly: - Blower Wheel - Primary Drain Pan - Electrical Wires Secured Tested condensate drain system: - Cleared Drain Line - Cleaned Out Primary Pan - Tested Safety Switch Other actions taken: - Wore Shoe Covers - Dusted
Today, I arrived on site and performed a summer time maintenance on your HVAC equipment. Here is a summary of my findings: Overall Equipment Condition: - Good Indoor Unit: - Location: Attic - Type: Air Handler - Picture: [Attach picture] - Area Unit Services: Upstairs/ downstairs Filtration: - Pleated 2-6" - Checked today Filter Size and Picture of filter: - 2) 20x25x5 - 1) 16x25x5 Condition of Indoor Coil: - Good - Clean Outdoor Unit: - Location: Side of House - Type: Heat Pump - Picture: [Attach picture] Condition of Outdoor Coil: - Good - Clean Tested and inspected these electrical components on your equipment and they are working properly within manufacturers recommended specs and amperage's: - Blower Motor - Condenser Fan Motor - Compressor - Blower Run Capacitor - Compressor Run Capacitor - Fan Run Capacitor - Contactor - Defrost Control Board - Electrical Wiring Inspected these components on your system and they are in good condition and working properly at this time: -
I did a summertime tuneup on your Goodman heatpump everything is working properly at this time in cooling mode View visual findings from this job here - https://visionshare.xoi.io/?id=XA-1026-CFDDAC940A964934847E616367EA4FC7
I did a summer time tuneup on your Goodman everything is working properly at this time
Today we performed a winter time tune up on your heat pump unit,everything is working properly at this time .Thank you for your business. Tallahassee FL
Today I performed a summertime tune up on your Goodman/ICP heat pump unit. Everything is working properly at this time. Thank you for your business. Eastpoint FL
I performed a Gold level Summer time tune on your equipment today. Checking the system’s operation. Thank you for your business today. Tallahassee, Fl
Today we performed a summer tune up on your Goodman heat pump unit, everything is working properly at this time. Thank you for your business. Eastpoint, Fl
Today I performed a winter time tune up on your ICP/Goodman heat pump unit. Everything is working properly at this time. Thank you for your business. Eastpoint FL