Today, I arrived on site to perform a summer time maintenance on your HVAC equipment. Overall Equipment Condition: * Equipment condition assessed as fair. Indoor Unit Details: * Located in the attic. * Serves the whole home. * Filtration system uses a pleated 1" filter (size 20x20x1). * Customer has spare filters but prefers to replace them independently. * Indoor coil condition noted as fair. Outdoor Unit Details: * Located in the back yard. * Type identified as straight cool. * Outdoor coil condition also assessed as fair. Electrical Components: * Successfully tested and inspected the following components: * Blower Motor * Compressor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Electrical Wiring * All tested components are functioning properly within manufacturer recommended specifications and amperages. System Components: * Inspected components in good working condition: * Blower Wheel * Primary Drain Pan * Electrical Wires secured * Secondary Drain Pan * No componen