Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Here's a summary of the work completed: System Assessment: Observed the overall equipment condition as fair. Confirmed the indoor unit is an air handler located in a closet, servicing the whole home. Verified the outdoor unit is a heat pump located in the back yard. Noted the customer will provide their own 12x30 filters. Observed the condition of both indoor and outdoor coils as fair. Electrical Components: Verified proper operation of the blower motor, heat strip kit, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring within manufacturer's specifications. Component Inspection: Confirmed the blower wheel, primary drain pan, electrical wires, and ductwork are in good condition and working properly. Condensate Drain System: Cleared the drain line. Cleaned out the primary pan. Tested the safety switch. Verified the d