Today I arrived on site and performed a summer time maintenance on your HVAC equipment. **Indoor Unit (Air Handler - Crawl Space):** * Replaced the 20x30x1 pleated 1" filter using customer-supplied spares. * Confirmed the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump - Side of House):** * Verified the outdoor coil is clean and in good condition. * Tested and inspected the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, contactor, and electrical wiring; all operating within manufacturer's specifications. * Inspected the blower wheel, primary drain pan, and secured electrical wires; all in good working order. **System Performance:** * Measured a return air temperature of 72.0°F and a supply air temperature of 55.0°F. * Cleared the condensate drain line, tested the safety switch, and cleaned out the primary pan. * Tested thermostat operation and restored power to the units. View visual findings