Dobbs Technician A.

Dobbs Technician A. Job Checkin

Arrived today due to 2013 Carrier not heating/cooling which is responsible for the entire house.Upon arrival thermostat was at 75° with a desired temperature of 74° on the main level & the upstairs thermostat was blank determined due to corroded batteries it has damaged the thermostat causing intermittent power to be supplied which makes thermostat intermittently power on and off a quote has been provided to replace thermostat.Tested functionality of equipment in cool/heat function confirming its ability to complete instructed functions but equipment was displaying an abnormal noise along with no airflow was being disturb through duct-work.Once finished with determining the operation went into attic finding furnace & zone board to be blank indicating power has been lost.Light switch was in the on position tested for voltage confirming no power was present went to the breaker finding breaker tripped indicating a high voltage issue.Reset breaker to the furnace regaining power to furnace


Dobbs Technician A.

Dobbs Technician A. Job Checkin

DCM2: AC complete, replaced 16x20x1 and 16x25x1 filters. Office system outdoor capacitor was out of manufacture range 40/5 34.3/4.7. Replaced capacitor and confirmed proper operations. Both systems are now fully functional and operating within manufacturer specifications. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Maintenance checklist attached. Set thermostats to 78 cool.


Keith D.

Keith D. Job Checkin

Quoted in hvacbizpro and emailed over - she didnt want a price after i told her approx. ranges then said that since i was here just go ahead and told me to email it to her


Dobbs Technician A.

Dobbs Technician A. Job Checkin

DCM2: Heat complete, replaced 16x20x1 and 16x25x1 filters. Both systems are fully functional and operating within manufacturer specifications at this time. Refrigerant pressures and temperatures are appropriate for indoor and outdoor weather conditions. Set thermostats to 64 heat. Maintenance checklist attached.


Cody C.

Cody C. Job Checkin

DCM2 service 2 of 2 Ac completed changed (1) 16x20x1 (1) 16x25x1 filters, tested system operation’s everything is operating properly at this time attached is Ac maintenance checklist.


Rob  S.

Rob S. Job Checkin

Arrived to No Cool Thermostat has completely failed. Reading 77* ( actually 71* ) with a set temp of 68. Thermostat was not calling for Cool. Replaced thermostat and tested system in Cool, Heat. Emergency Heat and Fan only. System functions as designed. AC diagnostics photos attached


Rob  S.

Rob S. Job Checkin

Arrived to no heat, found 5amp fuse blown, replaced fuse, system is now fully functional and operating within manufacturer design at this time.


Brad  N.

Brad N. Job Checkin

No a/c in showroom system above drop ceiling, found that the pump was full of water and pump was not running it did not have power, found that it was unplugged after searching it’s source down, pump is now pumping checked operation and found that the condenser fan capacitor was swollen and reading 0, replaced and checked operation system is running at this time.


Khalil W.

Khalil W. Job Checkin

Heat maintenance on 2-systems in Snellville