Technician arrived on reports the unit not heating technician came adjusted the temperature. The heat came on. Technician did make some airflow Adjustments the unit is heating properly at this time verified with manager as well as aman tech-support That the correct changes were made
Technician arrived to find that the core sense module had failed causing heat pump condenser not to run technician bypass. The core sense heat pump is operating as it should at this time. No issues were found technician checked airflow. Temperature split and refrigerant levels. Unit has no issues at this time.
Found the units flare on the outdoor unit leaking. Tighter the flare used soapy bubbles to insure no leaks and charged the system up. Unit is cooling good as of now.
14.3 SEER2 Heat Pump and Air Handler with Single Stage Heat Strips
Found the diaper system under the house messed up and a few holes in the duct work. Customer is going to wait at this time.
Replaced the condenser fan motor on a 2014 daikin Minisplit. System is cooling good at this time.
Cleaned both minisplit heads and installed mini split uv lights systems are cooling perfectly at this time.
Found the mini split heads severely dirty causing the blower speed error. Will return Monday to clean both heads and install uv lights.
Preformed yearly air conditioning maintenance. Found the unit low on refrigerant bad capacitor and compressor over amping on start up. Added one lb of refrigerant installed a plasma pure and added a new capacitor. System is working good at this time.
Found the 4 ton Goodman unit low on refrigerant preformed a leak search and found the leak in the coil.