910 Oak Tree Avenue
South Plainfield, NJ 07080
(888) 228-0917

Our Top Cities


Local Reviews
for springfield township, nj

Rated 5.0 out of 5 stars based on 6 customer reviews

Great service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Great service

  • Overall Experience
  • Quality
  • Convenience
  • Recommend

Fast service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Yearly testing

Very happy with the fast response from their office and the knowledge of the technician assigned to my service request.

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

good service and very professional

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for springfield township, nj

Eduardo  R.

Eduardo R. Job Checkin

Due to ongoing issues and overall poor condition of WPIV valve Confires recommends the following: Remove existing 6" WPIV from service including the NRS valve in the building downstream of the detector check. After removal of WPIV and NRS valve Confires will install a new 6" OS&Y valve in its place and will install a new OS&Y tamper. This will bring the control valve inside the building and is also compliant with NFPA standards. Customer will be responsible for patching wall where WPIV is and new tamper to be wired by others.


Kyle  R.

Kyle R. Job Checkin

Sprinkler and Backflow Inspection


Harry E.

Harry E. Job Checkin


Sean W.

Sean W. Job Checkin

On site to replace wpiv as per alarm company.


Sean W.

Sean W. Job Checkin

On site to repair FDC.


Harry E.

Harry E. Job Checkin


Eduardo  R.

Eduardo R. Job Checkin


Chris  C.

Chris C. Job Checkin


Jeremy B.

Jeremy B. Job Checkin


Eduardo  R.

Eduardo R. Job Checkin

Confirmed appt with Russell 973-420-4260 tech arrival: 8am The following discrepancies were found during your Annual Sprinkler Inspection that needs to be corrected for Compliance: 5 year internal inspection is due on (1) Dry system and must be completed per NFPA 25. Need to perform 5 year FDC Hydro test on (1) FDC per NFPA 25 section 13.7.4. We will pressurize the piping between the FDC connection and the FDC check valve to ensure its integrity. Please note that this test may identify issues and leaks that need additional repair. This quote covers the hydro test only and any issues including but not limited to defective piping, leaks, defective FDC connections, defective FDC checks or defective/leaking fittings will be quoted and repaired separately. Also note this test introduces water into piping that normally is dry and this test is designed to identify weaknesses in the FDC piping. Any weaknesses in the piping or components will begin to leak during this test which could lead to w


Jeremy B.

Jeremy B. Job Checkin


Eduardo  R.

Eduardo R. Job Checkin

GO AROUND TO THE RECEIVING SIDE OF THE BUILDING Confirmed appt with Mitch 973-376-0005 x520 Tech Arrival: 7/8am The following discrepancies were found during your Annual Sprinkler Inspection that needs to be corrected for Compliance: 2 heads on first floor are too high and the outer escutcheon will not stay on. These heads need to be lowered. Heads are located straight in front of main entrance towards back wall. 155 degree chrome pendant heads. Sprinkler Repair


Jeremy B.

Jeremy B. Job Checkin


Christian  W.

Christian W. Job Checkin


Harry E.

Harry E. Job Checkin