5402 Tower Rd
Tallahassee, FL 32303
850-562-3132

Job Locations
for tallahassee, fl


Map of Tallahassee FL
Ian B.

Ian B.


Job Checkin

Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Indoor Unit (Air Handler in Attic): Checked the pleated 20x20x1 filter (2-6" rating) and noted its condition. Observed the indoor coil condition. Outdoor Unit (Heat Pump on Side of House): Observed the outdoor coil condition. Tested and inspected the following electrical components, confirming they are working within manufacturer's specifications: Blower Motor Heat Strip Kit Condenser Fan Motor Compressor Blower Run Capacitor Compressor Run Capacitor Fan Run Capacitor Compressor Start Capacitor Contactor Electrical Wiring Inspected the following components, confirming they are in good working order: Blower Wheel Secondary Drain Pan Primary Drain Pan Electrical Wires Secured Ductwork System Checks: Measured a return air temperature of 67.0°F and a supply air temperature of 98.1°F. Cleared the condensate drain line and tested the safety switch. Confirmed the drain line is strapped. Restored power t