5402 Tower Rd
Tallahassee, FL 32303
850-562-3132

Job Locations
for tallahassee, fl


Map of Tallahassee FL
Lee G.

Lee G.


Job Checkin

Today I arrived on site and performed a winter time tune up on your system. **Indoor Unit (Air Handler in Closet):** * Verified the indoor unit is in good condition. * Confirmed the indoor coil is clean and in good condition. * Replaced the pleated 1" filter (size 18x18x1). * Customer requested additional filters for a charge. **Outdoor Unit (Heat Pump on Side of House):** * Verified the outdoor unit is in good condition. * Confirmed the outdoor coil is in good condition. **Electrical Components (Tested and Working):** * Blower Motor * Compressor * Blower Run Capacitor * Compressor Run Capacitor * Fan Run Capacitor * Contactor * Defrost Control Board * Electrical Wiring **System Components (Inspected and in Good Condition):** * Blower Wheel * Heat Exchanger * Primary Drain Pan * Electrical Wires Secured **Measurements:** * Return Air Temperature: 74.0°F * Supply Air Temperature: 105.2°F **Condensate Drain System:** * Cleared the