Today I arrived on site and performed a winter time tune-up maintenance on your HVAC equipment. **Indoor Unit (Air Handler - Garage, Attic):** * Replaced the 20x20x4 pleated filter. * Verified the indoor coil is clean and in good condition. **Outdoor Unit (Heat Pump - Side of House):** * Confirmed the outdoor coil is clean and in good condition. * Tested and verified proper operation of the blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring. **System Components:** * Inspected and confirmed the blower wheel, primary drain pan, secondary drain pan, electrical wires, and ductwork are in good condition and working properly. * Cleared the condensate drain line, cleaned the primary and secondary pans, and tested the safety switch. **Measurements:** * Measured a return air temperature of 130.0°F and a supply air temperature of 60.0°F. **Final Steps:** * Dusted the thermost