Today I arrived on site and performed a winter time maintenance on your HVAC equipment. Here's a summary of the work completed: Indoor Unit (Air Handler in Closet): Replaced the pleated 1" filter (size 18x20x1). Brush cleaned the indoor coil, which is in fair condition. Outdoor Unit (Heat Pump on Side of House): Visually inspected the outdoor coil; condition is fair. Electrical Components (Tested and Working): Verified proper operation and amperage of: Blower Motor, Heat Strip Kit, Condenser Fan Motor, Compressor, Blower Run Capacitor, Compressor Run Capacitor, Fan Run Capacitor, Compressor Start Capacitor, and Contactor. System Components (Inspected and Working): Confirmed good condition of: Blower Wheel, Primary Drain Pan, Electrical Wires Secured, and Ductwork. Condensate Drain System: Cleared the drain line and tested the safety switch. Verified the drain line is strapped. Measurements: Return air temperature: 70.0 Degrees Fahrenheit. Supply air temperature: 95.0 Degrees Fahr