Cristian  Z.

Cristian Z. Job Checkin

Changing settings on thermostat


Nixa G.

Nixa G. Job Checkin

R- 410a Adjust Refrigerant level: Every pound after 1st RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE Purge gauges to ensure no non-condensables enter system Use digital scale to weigh in refrigerant Adjust according to units TP chart and super heat and sub cool

R- 410a Adjust Refrigerant level: Every pound after 1st
RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE
Purge gauges to ensure no non-condensables enter system
Use digital scale to weigh in refrigerant
Adjust according to units TP chart and super heat and sub cool R- 410a Adjust Refrigerant level: Every pound after 1st
RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE
Purge gauges to ensure no non-condensables enter system
Use digital scale to weigh in refrigerant
Adjust according to units TP chart and super heat and sub cool

Charles B.

Charles B. Job Checkin

Arrived to home Found system down Breaker tripped Bad capacitors Contactor burnt Windings damaged

Arrived to home
Found system down
Breaker tripped
Bad capacitors 
Contactor burnt
Windings damaged Arrived to home
Found system down
Breaker tripped
Bad capacitors 
Contactor burnt
Windings damaged

Chris M.

Chris M. Job Checkin

air balance.


Cristian  Z.

Cristian Z. Job Checkin

A/h swap


Chris M.

Chris M. Job Checkin

Callback


Charles B.

Charles B. Job Checkin

New 5 ton Trane XV18 split system to be installed, Includes new outdoor condenser with new base pad and disconnect box, New attic air handler with new hanging system, secondary drain pan, properly sized insulated plenums with manual dampers included for the supply side. Touch screen Wi Fi thermostat included.


Charles B.

Charles B. Job Checkin

Arrived to home Set thermostat to cool Checked condenser Found following Disconnect melted (non fuse original from 2001) Contactor burnt and pitted Capacitor swollen at 0/0 Compressor windings over heated needs inrush kit


Charles B.

Charles B. Job Checkin

Arrived to home Checked system Found insulation panels in evap cabinet came loose and were against coil Found evap coil 75% plugged w debris Start amps high - loud start noise Clean evap coil Flush drain Secure insulation to panels on coil Install easy start


Chris M.

Chris M. Job Checkin

Sensor relocation.


Chris M.

Chris M. Job Checkin

Replace t5 sensor


Chris M.

Chris M. Job Checkin

Service.


Charles B.

Charles B. Job Checkin

I found system transformer tripped upon arrival. Verified low voltage wiring and reset. System is now communicating as it should. System is also low on r410a.


Chris M.

Chris M. Job Checkin

Arrived to home Checked system Settings good Temp split a little low Noticed discharge and SC fluctuating a little Will contact MFG on Monday


Charles B.

Charles B. Job Checkin

Provided maintenance on equipment and verified good operations. Compressor did have a shutter to its start. System is operating good at this time, suction pressure was a bit high for today’s indoor/outdoor temperatures but has good delta t (air temperature split) and good starting and operating amps. Noticed compressor has potentially experienced reverse rotation, would recommend a sure switch smart contactor with surge protection and short cycling protection to help prevent wear and tear on equipment.