Platinum Cool Home Membership Visit: Clean & rinse outdoor coil Apply UV protectant to outdoor unit (if plastic) Inspect condensate drain line System temperature split Test indoor & outdoor capacitors Check compressor & fan motors Inspect control boards Check electrical connections Inspect fan blade system Check system static pressure Clean or replace filters Inspect duct connections & insulation levels
The 1075 outdoor fan motor had gone bad. This had caused overheating issues with the compressor and damaging the capacitor for the compressor. I replaced the motor and capacitor and the unit is operating properly at this time. DESCRIPTION Platinum Cool Home Membership - 1 System Includes two maintenance visits per year Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $1,500) 10% Discount on any repair work needed $200 Discount on Home Performance upgrades https://www.idealairaz.com/flipbook/cool-home/?page=1
DESCRIPTION Cool Home Membership - 1 System Front of the line, priority service over everyone else, guaranteed service within 24 hours $97 diagnostic fee No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $500) https://www.idealairaz.com/flipbook/cool-home/?page=1
Clean Evaporator Coil: Easy Access Gain access to back side of indoor coil Brush indoor coil to remove large debris Spray coil with coil cleaner and rinse
Platinum Cool Home Membership Visit: Clean & rinse outdoor coil Apply UV protectant to outdoor unit (if plastic) Inspect condensate drain line System temperature split Test indoor & outdoor capacitors Check compressor & fan motors Inspect control boards Check electrical connections Inspect fan blade system Check system static pressure Clean or replace filters Inspect duct connections & insulation levels
Condensation safety switch had been knocked out of the float and laying on the landing. I reinstalled the switch and verified operations in the unit unit unit operating properly at this time.
- IRA Federal Tax Credit on insulation projects - Individual qualifications vary - Discount available for check payment *CLICK "VIEW MORE" on each line item to view included improvements
Arrived to home Checked thermostat Set for 72 Checked unit Found burnt C wire to compressor 2 - inrush kits installed (1-kickstart) Dual capacitor at 0/30&0/5 *fan motor may fail due to capacitor **compressor may fail due to having 2 inrush kits installed Performed repairs Had to cool compressor with water Inrush kit Amrad capacitor
Air handler is leaking water. Drained as much water possible. This issue appears to be on going. Draining water out is only a temporary fix. Recommendation is to run a new line. System is cooling at departure.
Visit 2 of maintenance plan done in cooling. 2 gas split units. Master unit was found with a faulty secondary pan and vent on drain pipe is too low, also on this unit the vent to the furnace has leaks and is a health concern. East unit has primary line clogged and second span needs re leveling. Both nits cooling at departure.
Arrived to home Found vent too low Drain plugged Water damaged wood and drywall Restoration company to do repairs on drywall and wood Sent quote for pump to eliminate drain issues in future due to termination point being ground level
The home has a ductwork issue. The upstairs is getting satisfied at 74° and the downstairs is staying hot 82 to 85°. I checked the system and found it properly charged and is producing a low temperature split of 16°. The true gauge readings and charge will need to be evaluated once the ductwork issues are resolved on the system to verify proper charge.
Arrived to home Checked thermostat Checked filter Flushed drain Checked system operations Cleaned condenser System operating normal at this time
I found 1 60a fuse had failed at disconnect. I checked and tightened all electrical connections, verified capacitors, and checked operation. System did start with higher than rated starting amps. But system overall is operating within desired ranges. System is operating fine at this time, would recommend soft start in rush kit to help lower starting amps and offer further protection to compressor.