Eric came and got the job done and cleaned up after themselves. We are pleased with the service. Thanks, Nellie Varvel and Clarence Varvel
Chris Martinez put 110 percent effort into figuring out my intermittent heat pump problem and fixing it as cost-effectively as possible. He was terrific! On another note, I really appreciate Ideal's constant communication about appointments and technician arrival times. Thank you for valuing my time, Ideal.
Matthew was ontime, tidy, personable, and thorough. we've been consistently pleased with Ideal's service through the years.
The team was great and finished in 1 day instead of 2 as scheduled.
A couple of months ago Ideal replaced my insulation, and air sealed my attic. Yesterday they were back to install an ERV (Energy Recovery Ventilation) system. Everything Idea does is best in class. They went above and beyond to help me get the HOA Architectural Request approved, quickly scheduled the installation once the project was approved, and everyone on the work crew was absolutely delightful. Big recommend for Ideal from me.
Ideal is, well, idea. Seriously. The response to my original RFQ was fast, as was scheduling. The technician was right on time and really cool about explaining everything to me so I understood my options (he provided Good, Better, Best). All around great experience. Highly recommend.
Found system running d55 or degrade on a t5 limiter I power cycled and tested in force mode system tripped at 15 minutes on a p4 t5 error to derate system. I contacted tech support to verify my findings and confirmed. System is low on refrigerant leak at indoor coil system has been de rating to protect compressor from overheating. Indoor coil will need to be replaced under manufacturer’s limited warranty in order for system to operate properly. Collected 50% down deposit today
50% customer deposit given to sales team Batt removal, To R49 cellulose, air sealing
I provided maintenance on equipment and verified good operations. System is operating fine at this time.
Inrush start assist Dual capacitor Waived after hours fee with membership Flushed drain (was plugged) Cleaned condenser coil Fan motor amps dropped from 1.7 to .8 Start amps dropped from 75.9 to 19.8
Arrived to home Found code 177.02 on thermostat history Started system Condenser tripped before could check Waited for second start Tripped out at 26+ amps (FLA 20.3) Hooked up gauges Third start Tripped- tripped with 22.7 SC and HP of 468 Amps continually extremely high upon trips Watered condenser coil on 4th start Pressures and amps dropped then rose to trip Removed 1.5# 410A Pressures, SC and amps all good Cooling home properly at this time
Membership Checked both systems See checklists for findings *5 ton system needed an easy start as the start amps were at OL
I provided maintenance on equipment and verified good operations.
- $2,000 IRA Federal Tax Credit System meets qualifications - Individual qualifications vary - Bosch Platinum Pro Certified Installation Package w/ Extended 11yr. Warranty - IRA Federal Tax Credit on insulation projects - Individual qualifications vary - May qualify for promotions, 0% for up to 60 months or low payment plans - Discount available for check payment *CLICK "VIEW MORE" on each line item to view included improvements
Arrived to home Set system to cool Checked float switch - dry Checked condenser Found dual run capacitor bad Changed capacitor - started system - working within mfg specs at this time
R38 Cellulose insulation, duct sealing, air seal, Soffit Baffles, Attic Hatch dam and insulation
DESCRIPTION Platinum Cool Home Membership - 1 System Includes two maintenance visits per year Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $1,500) 10% Discount on any repair work needed $200 Discount on Home Performance upgrades https://www.idealairaz.com/flipbook/cool-home/?page=1
Arrived to job Checked system Found jumper between “O” and “Y1” Found thermostat programmed incorrectly Set for energize in B Reprogrammed Bad disconnect Replaced disconnect Checked system - good at this time
Micro-Air FLEX: The most advanced & effective soft starter for all A/C applications 4-part start ramp sequence that is self-optimizing, resulting in the lowest possible start-up current. Start current reduction of up to 75% of a compressor's LRA Reduces blinking of lights when A/C starts at home Improves compressor start up and prolongs life of system UL listed with waterproof enclosure Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs
Spoke to landlord about warranty process through Goodman. Goodman warranties out the failed part. I replaced the failed component of the blower motor which was the module. A copy of the invoice reflecting our labor cost only has been emailed as well.