Best HVAC service by far

Ideal Energy had an amazing team from start to finish. Very thorough quoting process with detailed analysis of the home; multiple options all appropriately sized for the needs of the home, and excellent communication and installation. I had 3 other companies quote and the 2nd best was a distant 2nd.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for buckeye, az

Chris M.

Chris M. Job Checkin

QC

QC

Chris M.

Chris M. Job Checkin

Recommended replacement of existing zoning 08/12/25 Reinsulated section of lineset on exterior. I put system in dry mode, and verified good moisture removal. System is draining as it should.

Recommended replacement of existing zoning
08/12/25 
Reinsulated section of lineset on exterior. I put system in dry mode, and verified good moisture removal. System is draining as it should.

Nixa G.

Nixa G. Job Checkin

System is found with no Freon. Multiple leaks detected, one is at the core calve and the other on the copper pipe. Pipe rubbed against the compressors plug cap. I tested the compressor and it has open windings. System is need of a new compressor, braze repair, and contains r22 Freon. Spoke to homeowner over repairs and advised that for the age of the system new equipment install is also an option. System is down at departure.

System is found with no Freon. Multiple leaks detected, one is at the core calve and the other on the copper pipe. Pipe rubbed against the compressors  plug cap. I tested the compressor and it has open windings. System is need of a new compressor, braze repair, and contains r22 Freon. Spoke to homeowner over repairs and advised that for the age of the system new equipment install is also an option. System is down at departure.

Matthew B.

Matthew B. Job Checkin

The unit had a bad outdoor fan motor. This caused the compressor to overheat and damage the capacitor. I replaced the 825 outdoor fan motor and 70 capacitor. The unit is operating properly at this time. DESCRIPTION Platinum Cool Home Membership - 1 System Includes two maintenance visits per year Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $1,500) 10% Discount on any repair work needed $200 Discount on Home Performance upgrades https://www.idealairaz.com/flipbook/cool-home/?page=1

The unit had a bad outdoor fan motor. This caused the compressor to overheat and damage the capacitor. I replaced the 825 outdoor fan motor and 70 capacitor. The unit is operating properly at this time.

DESCRIPTION
Platinum Cool Home Membership - 1 System
Includes two maintenance visits per year 
Front of the line, priority service over everyone else, guaranteed service within 24 hours
Discounted $37 diagnostic fee (versus regular diagnostic fee of $97)
No weekend or after hour fees
100% of your protection plan goes toward your future system replacement (capped at $1,500)
10% Discount on any repair work needed
$200 Discount on Home Performance upgrades
https://www.idealairaz.com/flipbook/cool-home/?page=1

Cristian  Z.

Cristian Z. Job Checkin

HVAC installation in Buckeye

HVAC installation in Buckeye

Nixa G.

Nixa G. Job Checkin

DESCRIPTION Recovery Refrigerant & Check Charge Follow EPA guidelines to recovery excess refrigerant from system Let system stabilize and check pressure until system is within manufactures specifications Overcharged systems will have a decreased lifespan due to higher head pressure in the compressor Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs Thaw out coil Once excess refrigerant was removed and coils were thawed out refrigerant pressures were revised once again. System appears to have a liquid line restriction. Base repair recommended is to replace txv and add new refrigerant to ensure non condensibles are present. This does not guarantee there could be other underlying issues. Once initial repair is completed the system can be re evaluated if needed. Due to age of system it is also advised to consider new install of equipment. System cooling at its best capacity at departure.



DESCRIPTION
Recovery Refrigerant & Check Charge
Follow EPA guidelines to recovery excess refrigerant from system
Let system stabilize and check pressure until system is within manufactures specifications
Overcharged systems will have a decreased lifespan due to higher head pressure in the compressor
Non Members: 90 day parts + labor warranty on all repairs
Cool home members: 2 year parts + labor warranty on all repairs

Thaw out coil

Once excess refrigerant was removed and coils were thawed out refrigerant pressures were revised once again. System appears to have a liquid line restriction. Base repair recommended is to replace txv and add new refrigerant to ensure non condensibles are present. This does not guarantee there could be other underlying issues. Once initial repair is completed the system can be re evaluated if needed. Due to age of system it is also advised to consider new install of equipment. System cooling at its best capacity at departure.

Charles B.

Charles B. Job Checkin

Insulate both garage attics to R38 cellulose, Baffle dam & insulate both attic hatches


Chris M.

Chris M. Job Checkin

Attic inspection


Charles B.

Charles B. Job Checkin

Arrived to home Tested noise with decibel meter Max 79 @ compressor Min 72 @ 1’ distance Within acceptable limits for compressor noise Recommended compressor blanket to reduce noise Emailed estimate for easy start and compressor blanket


Charles B.

Charles B. Job Checkin

Arrived to home Discussed issues Set up ladder- set thermostat to call for cooling *1 - noise from condenser (2 ton) unable to replicate - started and stopped 3 times *2 - vibration from furnace (2 zone system larger) Found blower wheel out of balance Bypass damper installed improperly Discussed the incorrect ducting with zoned system


Chris M.

Chris M. Job Checkin

Air balance


Charles B.

Charles B. Job Checkin

Arrived to home Checked system Found compressor cap bad Windings starting to wear out **wrong size cap installed (was 50 requires 45) Rewired fan to 3 wire set up and replaced cap with correct size Installed start kit Start amps at 40A Start kit and Dual Capacitor


Charles B.

Charles B. Job Checkin

I provided a check up on equipment and verified good operations.


Matthew B.

Matthew B. Job Checkin

Returned an installed the driver and verified operation and the unit is operating properly at this time


Camari D.

Camari D. Job Checkin

Includes Air Sealing & insulation in Buckeye