Recommended replacement of existing zoning 08/12/25 Reinsulated section of lineset on exterior. I put system in dry mode, and verified good moisture removal. System is draining as it should.
System is found with no Freon. Multiple leaks detected, one is at the core calve and the other on the copper pipe. Pipe rubbed against the compressors plug cap. I tested the compressor and it has open windings. System is need of a new compressor, braze repair, and contains r22 Freon. Spoke to homeowner over repairs and advised that for the age of the system new equipment install is also an option. System is down at departure.
The unit had a bad outdoor fan motor. This caused the compressor to overheat and damage the capacitor. I replaced the 825 outdoor fan motor and 70 capacitor. The unit is operating properly at this time. DESCRIPTION Platinum Cool Home Membership - 1 System Includes two maintenance visits per year Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $1,500) 10% Discount on any repair work needed $200 Discount on Home Performance upgrades https://www.idealairaz.com/flipbook/cool-home/?page=1
DESCRIPTION Recovery Refrigerant & Check Charge Follow EPA guidelines to recovery excess refrigerant from system Let system stabilize and check pressure until system is within manufactures specifications Overcharged systems will have a decreased lifespan due to higher head pressure in the compressor Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs Thaw out coil Once excess refrigerant was removed and coils were thawed out refrigerant pressures were revised once again. System appears to have a liquid line restriction. Base repair recommended is to replace txv and add new refrigerant to ensure non condensibles are present. This does not guarantee there could be other underlying issues. Once initial repair is completed the system can be re evaluated if needed. Due to age of system it is also advised to consider new install of equipment. System cooling at its best capacity at departure.
Insulate both garage attics to R38 cellulose, Baffle dam & insulate both attic hatches
Arrived to home Tested noise with decibel meter Max 79 @ compressor Min 72 @ 1’ distance Within acceptable limits for compressor noise Recommended compressor blanket to reduce noise Emailed estimate for easy start and compressor blanket
Arrived to home Discussed issues Set up ladder- set thermostat to call for cooling *1 - noise from condenser (2 ton) unable to replicate - started and stopped 3 times *2 - vibration from furnace (2 zone system larger) Found blower wheel out of balance Bypass damper installed improperly Discussed the incorrect ducting with zoned system
Arrived to home Checked system Found compressor cap bad Windings starting to wear out **wrong size cap installed (was 50 requires 45) Rewired fan to 3 wire set up and replaced cap with correct size Installed start kit Start amps at 40A Start kit and Dual Capacitor
I provided a check up on equipment and verified good operations.
Returned an installed the driver and verified operation and the unit is operating properly at this time