4127 E University Dr
Phoenix, AZ 85040
480-839-0082

Local Reviews
for peoria, az

Rated 5.0 out of 5 stars based on 4 customer reviews

Great

Matt did a good job I would use y'all again and I would recommend you if I had the opportunity

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Well Done!

Communication was great, everyone was on time and the work was completed same day.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Answered all my questions and did exactly the way I wanted it. Installation and everything went smoothly

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for peoria, az

Matthew B.

Matthew B. Job Checkin

The unit was frozen over from a dirty Air filter. I defrosted the system and found it was slightly undercharged. I charge the unit back to factory specifications and the unit unit is operating properly at this time.

The unit was frozen over from a dirty Air filter. I defrosted the system and found it was slightly undercharged. I charge the unit back to factory specifications and the unit unit is operating properly at this time.

Charles B.

Charles B. Job Checkin

Returned to home Installed new condensate pump Connected safety switch Tested pump Working good at this time Unable to remove male connection at AHU due to proximity of line set Built fill pipe and left next to pump for testing Condensate pump

Returned to home
Installed new condensate pump
Connected safety switch
Tested pump
Working good at this time
Unable to remove male connection at AHU due to proximity of line set
Built fill pipe and left next to pump for testing

Condensate pump

Charles B.

Charles B. Job Checkin

Arrived to home Found drain double trapped Underground line is approximately 17’ before coming up outside Should have pump in lieu of standard drain Drain line also runs on door needs to be reworked May need Halo down the road

Arrived to home
Found drain double trapped
Underground line is approximately 17’ before coming up outside
Should have pump in lieu of standard drain
Drain line also runs on door needs to be reworked

May need Halo down the road

Charles B.

Charles B. Job Checkin

Arrived to home Checked system Turned on thermostat for casita Turned off all other thermostats Checked (accessible) zone dampers Found some set with high min close points One wired incorrectly (power open when should be power close) Found bypass damper damaged (stuck closed) Drain incorrect - missing float switch and clean out Evidence of water leaning into overflow pan Line set pushing on gas line (must be remedied) *Highly recommend installing mini split in casita and abandoning zone for room **Main system needs complete tune up - has 4 zones with inferior duct design ***Also recommend energy audit as home balance is incorrect Exhaust fan in guest room - damper is flapping (positive pressure in home) Estimated repairs

Arrived to home
Checked system
Turned on thermostat for casita
Turned off all other thermostats 
Checked (accessible) zone dampers
Found some set with high min close points
One wired incorrectly (power open when should be power close)
Found bypass damper damaged (stuck closed)
Drain incorrect - missing float switch and clean out
Evidence of water leaning into overflow pan
Line set pushing on gas line (must be remedied)

*Highly recommend installing mini split in casita and abandoning zone for room
**Main system needs complete tune up - has 4 zones with inferior duct design
***Also recommend energy audit as home balance is incorrect
Exhaust fan in guest room - damper is flapping (positive pressure in home)

Estimated repairs

Nixa G.

Nixa G. Job Checkin

There was a power outage in the neighborhood due to a severe thunderstorm last evening. 2 units, the unit to upstairs never powered back up after the outage. Found the breaker was flipped at the electrical panel. After switching it on the system powered on. The unit is now cooling.


Matthew B.

Matthew B. Job Checkin

Unit had a blown fuse from the thunderstorm. I replaced the fuse and the units operating proper.

Unit had a blown fuse from the thunderstorm. I replaced the fuse and the units operating proper.

Charles B.

Charles B. Job Checkin

Arrived to home Checked thermostat Checked system Found compressor windings damaged Capacitor at 0/0 of 80/7.5 Contactor Performed repairs Inrush kit Amrad capacitor Contactor Rechecked system System operating at this time Replacement advisable due to age/deterioration of compressor

Arrived to home
Checked thermostat
Checked system
Found compressor windings damaged
Capacitor at 0/0 of 80/7.5
Contactor

Performed repairs
Inrush kit
Amrad capacitor
Contactor

Rechecked system
System operating at this time 

Replacement advisable due to age/deterioration of compressor

Charles B.

Charles B. Job Checkin

Arrived to home Set thermostat to cool Checked system Pressures extremely low Found leak at bottom of unit inside 2 other spots close Recovered remaining refrigerant Repaired spots Pressure tested (held for 10 minutes) Evacuated (held for 10 minutes) Charged with 10# 410A Started and systems running properly at this time Changed flex flue in attic to 1 piece Membership

Arrived to home
Set thermostat to cool
Checked system
Pressures extremely low
Found leak at bottom of unit inside
2 other spots close
Recovered remaining refrigerant 
Repaired spots
Pressure tested (held for 10 minutes)
Evacuated (held for 10 minutes)
Charged with 10# 410A
Started and systems running properly at this time
Changed flex flue in attic to 1 piece

Membership

Charles B.

Charles B. Job Checkin

Arrived to home Set thermostat to cool Bad comp cap Separated CFM cap Wrong size wire jumper between C on both caps Windings damage from drop in cap on compressor Non fusible disconnect in place Dual Cap Inrush Kit Membership

Arrived to home
Set thermostat to cool
Bad comp cap
Separated CFM cap
Wrong size wire jumper between C on both caps
Windings damage from drop in cap on compressor 
Non fusible disconnect in place

Dual Cap
Inrush Kit
Membership

Charles B.

Charles B. Job Checkin

Arrived to home Set thermostat to cool Checked system Mechanically within MFG specs Inrush amps over limit Flushed drain Cleaned condenser Leveled condenser

Arrived to home
Set thermostat to cool
Checked system
Mechanically within MFG specs
Inrush amps over limit
Flushed drain
Cleaned condenser
Leveled condenser

Chris M.

Chris M. Job Checkin

Air balance


Charles B.

Charles B. Job Checkin

Arrived to home Found error ATL on condenser Checked thermostat RV was set to energize in cooling Switched to heat Daughter did manual reset this morning Working good at this time


Nixa G.

Nixa G. Job Checkin

Micro-Air FLEX: The most advanced & effective soft starter for all A/C applications 4-part start ramp sequence that is self-optimizing, resulting in the lowest possible start-up current. Start current reduction of up to 75% of a compressor's LRA Reduces blinking of lights when A/C starts at home Improves compressor start up and prolongs life of system UL listed with waterproof enclosure Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs Turbo 200X Capacitor Universal Run Capacitor Includes new run capacitor with professional installation Inspect wires & spade connectors for overheating & replace as needed Properly secure capacitor to unit inside cabinet Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs System is from 2007, contains r410a, additional recommendations are attached. Recommend maintenance for full annual evaluations.


Charles B.

Charles B. Job Checkin

Seal master air handler Remove and cap all ducts to HEPA3000 systems Halo (3) Rebuild condensate drain in *no charge to seal master air handler in attic **no charge to seal static pressure access points Returned and performed repairs


Cristian  Z.

Cristian Z. Job Checkin

Peoria project for insulation, hvac replacement and duct sealing. Encapsulate AC system area in attic, remove 50% batts, realign remaining batts. Insulate to R49 entire attic. Soffit Baffles Air Barrier seal. Duct seal system, Enlarge return duct. New mixing box with manual dampers, and larger supply connection duct to mixing box. Trane XR 14 split Gas electric system installation included