From home evaluation, detailed engineering and installation team the experience was professional, knowledgeable, friendly and on time.
I found outdoor drive board on ac unit 2 had failed. I replaced drive board under manufacture limited warranty and installed surge protectors on both units. Both systems are operating at this time.
The unit burnt a wire losing communication. I replaced the wire and verified operation. The unit is operating properly.
DESCRIPTION Platinum Cool Home Membership - 2 Systems Includes two maintenance visits per year Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $1,500) 10% Discount on any repair work needed $200 Discount on Home Performance upgrades https://www.idealairaz.com/flipbook/cool-home/?page=1
Split Heat Pump Install in Sun Lakes, AZ
Deposit for Mini Split Estimate in Sun Lakes
Capacitor; Part under warranty • Includes new run capacitor with professional installation • Inspect wires & spade connectors for overheating & replace as needed • Properly secure capacitor to unit inside cabinet • Non Members: 90 day parts + labor warranty on all repairs • Cool home members: 2 year parts + labor warranty on all repairs
Performed cooling inspection on 2 units. Found a bad capacitor to the bigger unit, condenser. Parts are under warranty. Will return to replace part.
Checked split system main home - flushed drain - cleaned coil - system within MFG specs at this time. Changed filters - customer asked for me only to come out going forward.
Checked system - found cracked seal on elbow to unit - changed filters - system operating within normal MFG specs at this time - flushed drain and cleaned unit
Performed an AC check on both systems. Did a heat check on the furnace one. The units are operating properly at this time.
The unit had a very slow flowing condensation line, causing the float to trip. I cleared out the condensate and poured a gallon of water through to verify that it drains properly. The unit is operating properly.
Performed cool home visit on both systems properly at this time
The home is only 1500 ft.² and the unit is a 5 ton. The unit experiencing extremely high static pressure SA.43 RA.56. The unit is producing a very high temperature split. I checked the settings and found the unit was set to a 4 ton with standard blower tap speeds.. I changed the blower speed to the lower settings and checked static pressure. The static pressure are in more acceptable range RA.35 SA.26 The unit is now producing a 23° split. The condensation line was an indoor style and the sun had melted it. I replaced the condensation P-trap to the proper dimensions for a Bosch unit. The unit is operating properly at this time.