Charles B.

Charles B. Job Checkin

Arrived to home Checked thermostats/sensor Found bad batteries on sensor in master Unable to connect thermostat to app Leslie will call Trane

Arrived to home
Checked thermostats/sensor
Found bad batteries on sensor in master
Unable to connect thermostat to app
Leslie will call Trane

Nixa G.

Nixa G. Job Checkin

Performed cooling test for inspection. Found system low on charge. System is only 2 years old. Low charge can be due to initial installation or possibly a minute leak. Refrigerant pressures will be documented on next maintenance visit and if pressures drop once again it will be recommended to perform a leak search. Additional recommendations are attached to help extend the life warranty f the compressor and other parts. System is cooling at departure.


Nixa G.

Nixa G. Job Checkin

Water leakage call. Found condensate line backed up. Cleared obstruction and added float switch. Water draining properly at departure.


Charles B.

Charles B. Job Checkin

Arrived to home Set thermostat to cool Checked indoor section Checked condenser Found following Bad dual capacitor (melted terminal and wire) Inrush amps high Drain needs to be rebuilt and flushed - 100% plugged Inrush kit Dual capacitor Float switch Trap and clean out *waived clean out and trap with repairs and membership **coupon for free inspection today with membership ***cleaned condenser no charge with repairs and membership


Charles B.

Charles B. Job Checkin

Arrived to home Set thermostat to cool Checked unit Found no clean out installed and hard plug in drain line (unable to clear with water or CO2 without clean out) Cleaned condenser coil System within MFG specs at this time Installed clean out and cleared drain line Due to drain not draining and vent being higher than system pan there is a potential for foreign growth inside unit. We will be able to assess further this fall during the fall maintenance.


Charles B.

Charles B. Job Checkin

I found outdoor drive board on ac unit 2 had failed. I replaced drive board under manufacture limited warranty and installed surge protectors on both units. Both systems are operating at this time.


Matthew B.

Matthew B. Job Checkin

The unit burnt a wire losing communication. I replaced the wire and verified operation. The unit is operating properly.


Matthew B.

Matthew B. Job Checkin

DESCRIPTION Platinum Cool Home Membership - 2 Systems Includes two maintenance visits per year Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $1,500) 10% Discount on any repair work needed $200 Discount on Home Performance upgrades https://www.idealairaz.com/flipbook/cool-home/?page=1


Charles B.

Charles B. Job Checkin

Split Heat Pump Install in Sun Lakes, AZ


Chris M.

Chris M. Job Checkin

Install measurements.


Charles B.

Charles B. Job Checkin

Deposit for Mini Split Estimate in Sun Lakes


Nixa G.

Nixa G. Job Checkin

Capacitor; Part under warranty • Includes new run capacitor with professional installation • Inspect wires & spade connectors for overheating & replace as needed • Properly secure capacitor to unit inside cabinet • Non Members: 90 day parts + labor warranty on all repairs • Cool home members: 2 year parts + labor warranty on all repairs


Nixa G.

Nixa G. Job Checkin

Performed cooling inspection on 2 units. Found a bad capacitor to the bigger unit, condenser. Parts are under warranty. Will return to replace part.


Charles B.

Charles B. Job Checkin

Checked split system main home - flushed drain - cleaned coil - system within MFG specs at this time. Changed filters - customer asked for me only to come out going forward.


Charles B.

Charles B. Job Checkin

Checked system - found cracked seal on elbow to unit - changed filters - system operating within normal MFG specs at this time - flushed drain and cleaned unit