Arrived to home Found multiple water spots in ceiling Checked in attic (as far as I could get) Insulation appears dry Could be leak from roof or water line Packaged unit on opposite side of roof (3/12 pitch) Drain plugged and level with termination Removed trap Replaced and added clean out Draining termination good **leak appears to be coming from ridge vent (a lot of nails popped and doesn’t look sealed) Drain clear
Checked system Found 80uf cap at 3.92 Replaced cap Started system Working good at this time *in fall will need trap cut in to drain along with system cleaning Capacitor
Arrived to job Checked system Multiple issues with unit System from 2002 See service checklist for details
found oily stains on the condenser coil. I did a leak search and found the unit was leaking on a tube going through the steel plate for the edge of the coil. I displaced the metal plate and braised the leak shut. I charged the unit back to factory specifications and added the missing Freon caps. The unit is operating properly now.
Checked both thermostats Both working good at this time Waived service fee with membership Wants membership service for March/April 2026
Air Barrier seal, Insulation R30 added, Duct sealing
Found system with bad comp cap High start amps Installed new components Pressures and split low No evidence of leaks Recommend replacement
DESCRIPTION Preferred Cool Home Membership - 1 System Includes two maintenance visits per year for 1 system Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) 100% of your protection plan goes toward your future system replacement (capped at $1,000) https://www.idealairaz.com/flipbook/cool-home/?page=1
DESCRIPTION Cool Home Membership - 1 System Front of the line, priority service over everyone else, guaranteed service within 24 hours $97 diagnostic fee No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $500) https://www.idealairaz.com/flipbook/cool-home/?page=1
The thermostat just had bad batteries replace the batteries verified operations. The unit is operating properly.
Install duck board in platform return insulated kitchen vent, and fixed knee wall issue
Performed an AC check on both systems. Both systems are performing poorly. The units are producing poor temperature splits, and have bad capacitors in the air handlers. The 3 ton condenser needs a contactor service valve replacement and charged. The outdoor fan motor is failing as well. Recommend, replacing the system due to the age and poor performance of the units