Found system with bad comp cap High start amps Installed new components Pressures and split low No evidence of leaks Recommend replacement
DESCRIPTION Preferred Cool Home Membership - 1 System Includes two maintenance visits per year for 1 system Front of the line, priority service over everyone else, guaranteed service within 24 hours Discounted $37 diagnostic fee (versus regular diagnostic fee of $97) 100% of your protection plan goes toward your future system replacement (capped at $1,000) https://www.idealairaz.com/flipbook/cool-home/?page=1
DESCRIPTION Cool Home Membership - 1 System Front of the line, priority service over everyone else, guaranteed service within 24 hours $97 diagnostic fee No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $500) https://www.idealairaz.com/flipbook/cool-home/?page=1
The thermostat just had bad batteries replace the batteries verified operations. The unit is operating properly.
Install duck board in platform return insulated kitchen vent, and fixed knee wall issue
Performed an AC check on both systems. Both systems are performing poorly. The units are producing poor temperature splits, and have bad capacitors in the air handlers. The 3 ton condenser needs a contactor service valve replacement and charged. The outdoor fan motor is failing as well. Recommend, replacing the system due to the age and poor performance of the units
Performed cool home maintenance on both gas package units Systems both operating properly at time of visit
Arrived to home and unit was not cooling correctly, when I got on roof I found water pouring down roof due to it thawing from being frozen. My gauges showed unit was extremely low on refrigerant. Unit is 23 years old and I recommend not dumping a bunch of money into this system and to get a comfort consultant out to give him some quotes. Ryan will be out 12-3 today. Unit is not running at departure.
The unit has a bad outdoor fan motor. The unit has been overheating the compressor and the capacitor for the compressor. Tested bad. The contactor switch was burnt and needs replaced. I replaced the 825 outdoor fan motor, capacitor and switch the units operating properly.
No charge flipped it over to Ryan to give a quote. Originally homeowner said that unit would not turn off. The thermostat was having issues when I was there and she has wiring that is really bad and shorting out. When I got there today I found the compressor was overheated. It’s just pulling really high amperage and I don’t have anything to compare it to because the manufacture specs are gone. There’s just too many items that need to be fixed on that unit. I strongly suggested replacing it. Unit is not running at departure.
Arrived to home and homeowners unit was completely down, there was a bad duel cap and burned wiring. got them cooling but there’s other problems that really need to be addressed if they plan on keeping this old unit. The low voltage wire is falling apart and shorted outside and inside unit and Contactor is not in good condition. Also unit is low on refrigerant. I don’t reccomend putting a bunch of money in unit as it’s very old. Homeowner is expecting a call from office to get a comfort consultant out to give a quote on a new unit. Unit running at departure.