4127 E University Dr
Phoenix, AZ 85040
480-839-0082

Local Reviews
for gilbert, az

Rated 5.0 out of 5 stars based on 6 customer reviews

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Very thorough and knowledgeable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great company.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Professional

The staff was exceptionally efficient and professional. They were quiet and neat.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very prompt and professional.

Very knowledgeable and took the time to answer all of our questions.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for gilbert, az

Nixa G.

Nixa G. Job Checkin

Mini split is having a hard time to cool down the garage. Appeared to be low on charge. Initial split was about 17. Performed a leak search but did not find any signs of a leak at this time. With further investigation found a very dirty blower. Recommended to clean blower prior to adding charge as it could be a corporate to the issue. After cleaning blower the split improved to a 33 degree split. Verified refrigerant levels one more time. Added .8 oz of 410a and the split is now 40 degrees. So recommended to continue their annual check up so levels can be checked prior to next years summer and verify levels have maintained. Ductless system blower wheel cleaning Disassemble indoor unit and remove blower wheel Clean and rinse indoor blower wheel Removes dirt buildup and improves airflow and capacity R- 410a Adjust Refrigerant level: 1st Pound RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE Purge gauges to ensure no non-condensables enter system Use digital scale to weigh in

Mini split is having a hard time to cool down the garage. Appeared to be low on charge. Initial split was about 17. Performed a leak search but did not find any signs of a leak at this time. With further investigation found a very dirty blower. Recommended to clean blower prior to adding charge as it could be a corporate to the issue. After cleaning blower the split improved to a 33 degree split. Verified refrigerant levels one more time. Added .8 oz of 410a and the split is now 40 degrees. So recommended to continue their annual check up so levels can be checked prior to next years summer and verify levels have maintained. 

Ductless system blower wheel cleaning
Disassemble indoor unit and remove blower wheel
Clean and rinse indoor blower wheel
Removes dirt buildup and improves airflow and capacity

R- 410a Adjust Refrigerant level: 1st Pound
RECOMMEND LEAK SEARCH BEFORE ADJUSTING REFRIGERANT CHARGE
Purge gauges to ensure no non-condensables enter system
Use digital scale to weigh in

Charles B.

Charles B. Job Checkin

Spot on ceiling turned out to be a crack from install and not a water spot. I also established first and second stage on equipment and programmed thermostat for 2 stage fan operation. I measured static pressure with restrictive air filter and without. Would recommend using a lesser pleated filter to help keep static pressure within units desired range. Equipment is operating fine at this time.

Spot on ceiling turned out to be a crack from install and not a water spot. I also established first and second stage on equipment and programmed thermostat for 2 stage fan operation. I measured static pressure with restrictive air filter and without. Would recommend using a lesser pleated filter to help keep static pressure within units desired range. Equipment is operating fine at this time.

Charles B.

Charles B. Job Checkin

Arrived to home Checked system Found no 24V going to condenser Went into attic Found Bosch condenser connected to 2005 Carrier coil with 76 piston (should be TXV) No surge protectors in place Overflow pan with standing water No clean out for drain No float switch Reset system Came back on line Temp split fluctuating (due to lack of TXV) Spoke with Ron regarding concerns of system

Arrived to home
Checked system
Found no 24V going to condenser
Went into attic
Found Bosch condenser connected to 2005 Carrier coil with 76 piston (should be TXV)
No surge protectors in place
Overflow pan with standing water
No clean out for drain 
No float switch


Reset system
Came back on line
Temp split fluctuating (due to lack of TXV)

Spoke with Ron regarding concerns of system

Nixa G.

Nixa G. Job Checkin

Performed cooling inspection on 2 units. No issues found at this time. One of the three filters were replaced today, homeowner supplied. Ran out of filters to replace the other 2. Mini split in garage recommend to clean blower wheel for maintenance purposes. Both system cooling at departure.

Performed cooling inspection on 2 units. No issues found at this time. One of the three filters were replaced today, homeowner supplied. Ran out of filters to replace the other 2. Mini split in garage recommend to clean blower wheel for maintenance purposes. Both system cooling at departure.

Eric  A.

Eric A. Job Checkin

Trane HVAC replacement and ductwork in Gilbert. 36 months 0% o.a.c. with $4,000 deposit

Trane HVAC replacement and ductwork in Gilbert. 36 months 0% o.a.c. with $4,000 deposit

Charles B.

Charles B. Job Checkin

HVAC install Bosch AC in Gilbert with duct modifications

HVAC install Bosch AC in Gilbert with duct modifications

Nixa G.

Nixa G. Job Checkin

System is set to quiet mode in attempt of providing Temporary cooling. Need to order compressor for repair. Will reach out to homeowner with any update from Trane’s supply house for availability of parts. If home is not comfortable to stay in we might have a portable ac that can be lend out if needed. System is partially cooling at departure.

System is set to quiet mode in attempt of providing Temporary cooling. Need to order compressor for repair. Will reach out to homeowner with any update from Trane’s supply house for availability of parts. If home is not comfortable to stay in we might have a portable ac that can be lend out if needed. System is partially cooling at departure.

Ryan T.

Ryan T. Job Checkin

Energy audit in Gilbert


Matthew B.

Matthew B. Job Checkin

Verified the leak on the indoor coil. Documented units, models and serial number. Homeowner is going to get quotes for unit replacement or furnace and coil match up to the newer condenser.


Charles B.

Charles B. Job Checkin

Trane HVAC System Install in Gilbert


Matthew B.

Matthew B. Job Checkin

DESCRIPTION Preferred cool membership visit: 2 System Clean & rinse outdoor coil Apply UV protectant to outdoor unit (if plastic) Inspect condensate drain line System temperature split Test indoor & outdoor capacitors Check compressor & fan motors Inspect control boards Check electrical connections Inspect fan blade system Check system static pressure Clean or replace filters Inspect duct connections & insulation levels


Camari D.

Camari D. Job Checkin

Insulation instillation in Gilbert


Matthew B.

Matthew B. Job Checkin

Installed and set up the 1050 thermostat the unit is operating properly


Camari D.

Camari D. Job Checkin

Customer 50% Deposit - IRA Federal Tax Credit on insulation projects - Individual qualifications vary - May qualify for promotions, 0% for up to 60 months or low payment plans - Discount available for check payment *CLICK "VIEW MORE" on each line item to view included improvements


Matthew B.

Matthew B. Job Checkin

The unit had a blown fuse at the disconnect. I checked over the unit and did not find any issues to make a fuse blow. I did find some signs that the compressor possibly had been spinning backwards from a power interruption or a low-voltage chatter. I recommended a true soft inrush kit to provide short cycle protection, and to reduce the excessively high starting amperage, the unit is suffering from. I performed the first year membership visit for the homeowners. Cool Home Membership - 1 System Front of the line, priority service over everyone else, guaranteed service within 24 hours $97 diagnostic fee No weekend or after hour fees 100% of your protection plan goes toward your future system replacement (capped at $500) https://www.idealairaz.com/flipbook/cool-home/?page=1