I have been in my attic adding Ethernet lines and checking for duct leaks, these guys had to replace a long run duct that collapsed, remove the old unit and reinstall the new unit. They spent the day working away at it and by evening we had cool air flowing in our house again. They cleaned up after themselves and laid down paper and drop cloths to keep our house clean. Great Job.
No issues installing external system. Enough air flow to keep house cool until system parts are in.
Your service was great! He arrived early (after calling to ensure I'd be home) and after examining the A/C, said it was doing well. He was very pleasant and I'm very pleased to know that the unit will be serviced well every 6 months!
The folks at Ideal did a great job replacing our AC system, old ductwork, exhaust fans and insulation where needed. Very organized, fast and great cleanup. They are our "go to" folks for AC work in the future.
I checked the zoning system. I could not re-create the issue that was happening. The great room was opening and closing as prompted. I jumped the zoning system out multiple times to verify no issues with the motors or the zoning. The unit is operating properly at this time
2 Ton System was locked out again. Was able to get it going temporarily but will need to look into replacing the compressor or the system.
HVAC replacement and insulation installation in Chandler
Cool Membership visit: Inspect condensate drain line System temperature split Test indoor & outdoor capacitors Check compressor & fan motors Inspect control boards Check electrical connections Inspect fan blade system Check system static pressure Clean or replace filters Inspect duct connections & insulation levels
I found outdoor fan not operating. I tested capacitor and found it had failed, I also tested compressor capacitor and found it out of range. I replaced both capacitors with a turbo 200. I also found that outdoor fan motor has been wired incorrectly. I reheaded contacts and wired correctly. Tested equipment and verified good operations.
New 3 ton Package Heat pump R30 insulation, New Metal elbow, Disconnect, Stand, and cap rooftop Gas line in Chandler
Standard Inrush Kit 1-3 Ton Inrush kits significantly reduces the amount of time it takes for your air conditioner to start Powerful multi-layer starting capacitor and a smart switch to give compressors the boost they needs to start up quickly, more reliably, draw less power and save money, Non Members: 90 day parts + labor warranty on all repairs Cool home members: 2 year parts + labor warranty on all repairs
The unit was displaying a low charge. The outdoor fan motor capacitor tested bad. The contactor is burnt from the inrush device failing. I found oily stains on the indoor coil and it registered a leak with the leak detector and a service port needs replaced. Recommended replacing the system due to the scope of repairs
Arrived to home Checked thermostat Blower running not condensing side Went onto roof Found at 4 flash (hard lock out) Checked start amps (good) Run amps on all motors good Temp split at 21 degrees Fan motor at 120 degrees No horizontal play Capacitor good Contactor good Checked blower and found insulation separated from panel onto housing Secured insulation Amps on blower dropped and temp split went up Possibly insulation was suffocating blower
Arrived to home Found evidence of water coming from return duct Checked unit Found drain 90% plugged No clean out installed Start amps at OL Contactor burnt and pitted Indoor section dirty
Checked system Found compressor valves failing SC low Recommend system replacement over compressor Ryan coming out tomorrow to quote
Checked both systems West system Drain was 100% plugged Cleared drain with CO2 and shop vac Low on refrigerant Fan motor failing After adding refrigerant SC went from 3.4 to 8.3 with MFG spec at 10 +/- 3 East system running within mfg specs at this time Cleaned both condensers Waived coil cleaning and drain flush charge with membership
Arrived to home Changed filter Lowered point Checked system System within mfg specs at this time Cleared drain Cleaned condenser coil