31JUL2023 Jason Brown Arrived for previously bid mini split drain line replacement. Spoke with Key about the scope of work. While the handyman was out the cassette Evap was leaking, will you look at it. Verify materials. Disconnect power to 3 indoor head units, disassemble covers and remove existing damaged drain line. Pull new drains through existing drain line. Using hose clamps connections tie in drains to Evap pan. Reassemble head units and seal penetration with paintable silicone. Drop drain into exterior pvc. Resecure drain with 1 hole clamps. Cycle all units into cooling and verify no leaks. Inspect cassette and found 1’ ton of lineset uninsulated and dripping. Using homeowner provided materials I insulated the rest of the lines. Set all systems to 75 degrees and requested key do a quick check when she returns to verify no leaks. System is cooling properly at this time.