Performed camera inspection of drain line for sinks for kitchen, and found several sections where the bottom of the drain was gone. Ran camera all the wa to walk in freezer and was unable to get past the turn to see if there where any further issues. Unfortunately in this circumstance epoxy linning isn’t a viable option and recommend performing saw cutting and jackhammering of concrete to perform repair. In order to perform repair we will need to jackhammer and expose floor drain where clesnout is located as well as saw cut and jackhammer approximately 10’ in walk in cooler. This estimate is for performing repairs after hours Performed repair as outlined in invoice. Once we got to where the 2” lines drops down into the main we found that the line increased to 4” and 90 towards the unit next door. This section of 4” was completely missing bottom of the pipe. We attempted to tunnel as far as possible in attempt to find a good section of pipe to connect to but the bottom of the pipe wa