Completed for maintenance on a split system unit Checked all wiring and components Tested refrigerant levels, and temperature Tested capacitor Tested fan and compressor amps Hose down condenser coil Vacuum and flush condensate line Took temperature splits from supply and return Sprayed coil cleaner on the evaporator coil Checked air handler cabinet cleanliness Checked filter Unit is up and operating at this time Customers disconnect box at the condenser has been bypassed and there’s no way to safely turn off the power without going to the breaker panel. I do recommend getting this fixed as it is a safety concern for tax coming to work on your unit as well as there’s no Safeway to turn the unit off in general if something were to go wrong. Your capacitor is also slightly out of range and could be replaced. I got you signed up on the membership now so we’ll see you again in six months but that will give you the discounted prices on everything