Technician was knowledgeable and fixed the issue quickly.
Always good to work with the Comfort Central Team. I have referred them to 3 of my neighbors!
Wonderful and looking forward to having CC service my units!
I feel ready for summer and hot weather with good service.
Cameron, once again, provided excellent service on our HVAC system. He also cleared the evaporation line and emptied the back-up bucket on our crawlspace dehumidifier. You really can't put a price on service technicians who see things that need doing and do them! Cameron is all aces. The absolute best technician I've ever had service anything.
Cameron arrived on time with a smile and went above and beyond the required service.
Cameron Schumann did an excellent job. Thorough. Courteous. Professional.
Performed cooling tune up service on dual fuel system and minisplit system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drains, changed customer provided uv bulb. Everything looks and runs great!
Performed cooling tune up service on both cooling systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drains and condensate pump. Everything looks and runs great!
Performed heat pump cooling tune up service checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain. Everything looks and runs great!
Performed cooling tune up service on air conditioning system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain. Everything looks and runs great!
Found outdoor unit run capacitor has failed causing outdoor fan motor not to come on and unit cycle on thermal protection. Replaced capacitor and cycled unit to check operation. Everything runs normally again.
Found capacitor wiring loose, not making a good connection in outdoor unit. Reseated capacitor wire and cycled system to check operation.
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications
Found dehumidifier not throwing a fault code - performed hard reset on system by pulling the plug and cycled to check operation. Have 25° temperature rise across dehumidifier. Waited for dehumidifier to make water. Everything appears to run normally again.
Reset breakers and cycled system to check operation - surge protector still active and good. Everything runs normally again.
Found Mitsubishi unit in living room to be packed with dirt on the blower wheel found back bedroom on left to have some dirt on it but not packed with dirt where it’s falling off like what’s in the living room room. The blower wheel should be pulled and cleaned. top floor should be pulled and clean in a couple years. It’s not that bad. We pulled and cleaned the indoor blower wheel cleaned the unit and got rid of all the biological growth in. It started everything up and tested. It works fine. Looks good pictures included.
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Found blower motor capacitor to be bad. It needs to be replaced and we replaced it.
On inspection of the outdoor unit, I noticed that the two going to the TXB on the unit as possible. This would have to be replaced for heating. Found compressor should be using the internal bypass for the refrigerant being pressure is equal, which is the possibility that is the reason why the thermal overload when we got here. The system is 15 years old and I recommend it . The compressor was drawing almost 12 A which is about double of a new system.
Found common wire for capacitor had fallen loose causing compressor not to run - checked capacitor - replaced capacitor under warranty- recrimmped wire - cycled system to check operation.
Found capacitor has failed - attempted to replace capacitor and found compressor not starting and over amping - tried to add a hard start kit and still would not start. Recommend replacement of unit will follow up with an estimate to repair or replace system.