Cameron S. Job Checkin

Performed AC maintenance tune up service on both Bosch systems checking all electrical components, refrigerant balance, unit start up, operation, shut down, cleaning of indoor and outdoor coils, and treatment of drain lines and condensate pump. Serviced dehumidifier cleaning filter and treating drain. Everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

Found capacitor for unit had failed causing unit to buzz and not come on - replaced capacitor and cycled system to check operation - disabled humidifier per customer request. Everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

Believe door to unit was oil canning after reseating door everything seems to operate normally.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Found first floor system to be low on refrigerant sh-38 sc-2. Added to manufacturer specs Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications


Cameron  S.

Cameron S. Job Checkin

Found Schrader core on high pressure side had started to leak replaced Schrader core and added 2 lbs r410a to system and cycled to check operation. Everything runs normally again.


Jay E.

Jay E. Job Checkin

2-Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Furnace is cycling off on high limit. This is an R 22 system in order to get to the coil. We wouldhave to cut a 2 inch pipe and the drain pipe to get the door off and possibly get to the coil. tested heat pump operation. No issues found there. I would start considering replacing your system as it is well over 20 years


Kelsey T.

Kelsey T. Job Checkin

Upstairs Bosch unit: delta T of 33F. Suction line temp 140F with an outdoor ambient of 62F. Indoor 63F. Heat kit working. Checked aux pan for water. Brushed out drain trap. Tested aux pan switch and SS2. System is functioning normally Downstairs Bosch: 10 ppm CO, 11% O2. Filter will need to be changed. Burners are clean. Inspected blower and inducer. Gas valve falls to 0 ppm on shutdown. Tested condensate pump. System set to 40 degree lockout for back up heat. System is functioning normally.


Jay E.

Jay E. Job Checkin

Ran 10 g wire to heat pump


Jay E.

Jay E. Job Checkin

EQUIPMENT SPECIFICATIONS SEER2 20, HSPF2 9.5, EER2 13 Make: Bosch Model: BOVA-36HDN1-M20G Heat Pump BVA-24WN1-M20 Fan Coil 10 KW Electric Heat Tech Pure Merv 11 media filter Installation shall include: Equipment specified above plus materials and labor to include: • Required Electrical for Installation of Equipment. • We will remove the return air grill in the mechanical room and add a main return duct above the door to the mechanical room. • Permit Fee for Installation. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Bosch Factory Warranty: Ten (10) Year Limited Parts including Compressor. • First Year Comfort Club Membership is included. • One year Labor Warranty Provided by Comfort Central, Inc. • Ten (10) Year Guarantee on Comfort Central, Inc. Workmanship


Kelsey T.

Kelsey T. Job Checkin

CO 6 ppm, O2 8.7. Found mice in furnace. Removed mice and bedding. Repaired torn insulation on copper line. Taped sun damaged two-wire outside. Treated outdoor coil with cleaner. Brushed burners. Tested gas valve. System is functioning normally.


Kelsey T.

Kelsey T. Job Checkin

Main floor furnace: Tstac 103 F, CO 7 ppm, 9.6 O2. Changed filter. Checked condensate pump. Burners clean. Inducer fan clean. Checked dampers and purge cycle. System is functioning normally. Upstairs furnace: Tstac 128, CO 4 ppm, O2 was 14% before gas valve adjustment and 9.8 after. Changed filter, checked burners, and checked blower. Inducer working correctly. Checked dampers and condensate line. System is functioning normally.