Love Cameron! Always so pleasant and knowledgeable. I would highly recommend them for your service.
Cameron was very thorough, courteous, and effective. He did a great job!
Jay was prompt, friendly and efficient. Comfort Central is the best!!
I am most happy with your expert service. The problem was discovered and repaired efficiently. Thank you once again for superb service.
Cameron showed up early, quickly diagnosed the problem, and had it repaired in about half an hour. Great service. It exceeded my expectations.
Cameron was so kind, knowledgeable and professional. I would highly recommend him and the copany
Kelsey was great. He was easy to ask questions of and very knowledgable.
Cam was great as usual. I have been a customer with Comfort Central about from the beginning. Over the years they have installed heating and cooling systems in each home every time I have moved. I have always been very happy with their service, workmanship and products.
The Comfort Central technicians were very courteous and professional. The details of the job were clearly explained, and the pricing was very reasonable. I'm impressed with this company and would highly recommend.
Performed heating tune up on gas furnace system checking all burners, safeties, flame sensor, blower, performed full combustion analysis on system. Everything looks and runs great!
Found dirty flame sensor causing unit to lock out on ignition fault - performed tune up on gas furnace system and checked operation of furnace. Cleaned burners, flame sensor, checked safeties, all electrical components, gas pressure. Everything looks and runs great!
Performed heating maintenance tune up service on gas furnace system - adjusted damper position to make sure no air bypasses when one zone isn't calling - performed full combustion analysis - checked gas pressure - cleaned burners - cleaned flame sensor - cleared drain line - tested condensate pump - tested all system safeties. Everything looks and runs great!
Performed heating maintenance tune up service on two gas furnace systems checking combustion, gas pressure, unit start up, operation , shutdown. Cleaning of flame sensors, burners, and drains. Everything looks and runs great!
Performed heating maintenance tune up service on gas furnace system. Checked all electrical components, safeties, cleaned burners and flame sensor, checked drains, checked system gas pressure, start up, light off, operation, shutdown, checked AC refrigerant balance.
• Removal and replacement of radiant heating Manifolds, zone valves, thermostats and controls. • The new manifolds and zone valves are manufactured by Caleffi. The thermostats and controls will be Honeywell. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Caleffi Manufacturer’s Warranty: Two (2) Year Limited Parts. • Honeywell Manufacturers warranty: Five (5) years parts. • One (1) Year Labor Warranty Provided by Comfort Central, Inc.
Ultimate Heating Tune-Up Heat Pump: serviced and inspected heat pump system, including electrical, safeties, controls, reversing valve and defrost cycle to manufacturer specifications. No issues found today
Found wire from pressure switch had rubbed against copper on outdoor unit and was shorting out. Put electrical tape around wire and around copper where wires could rub. System is now working properly.
Found capacitor flat and leaking - replaced capacitor - cycled system to check operation - compressor was out on thermal - allowed unit condenser fan to cool unit - compressor started up normally - checked system operation.
Found no cool freezing up issue caused by new damper actuator not fully aligned with zone damper. Adjusted damper position and reseated damper actuator to fully open and close when calling and not calling for air. No charge as falls under our workmanship and labor warranty.
Repaired wires to contactor and disconnected Duke energy progress cycling device from system as it has burned wires. Cycled system checking operation. System appears to be working normally again. System is old r-22 refrigerant system - refrigerant phased out in 2016 - system appears to be holding charge well. Checked compressor amperage, outdoor fan motor amperage, capacitor, contactor, and outdoor disconnect electrical connections. Could not pull model or serial # off outdoor unit as has faded over time.
Performed AC maintenance tune up service for furnac + straight AC system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain line, and treatment of condensate pump.
Found main breaker on a/c to be tripped. Reset breaker turned unit on. Large spark happened at contactor. Found melted wires at contactor. Both L1L2 wires have heading that is melted Had to trim a bush next to air conditioner, so I could get to the service panel on the air conditioner. In doing so disturbed a yellow jacket nest in the bush. I think they were coming out of the ground. I’m not sure I couldn’t get close. You’ll need an exterminator to kill the yellow jackets when that happens. Call us back out and we’ll try to figure out What shorted on your air conditioner. Indoor breaker is off. Outdoor service disconnect is out. I was able to put a garbage bag over the top of the unit because I couldn’t put the service panel door back on.
No air to front bedroom. Checked 8 inch duck going to front bedroom no issues found found zone one damper partially open when it should’ve been all the way open. The damper was actually deflecting air away from the 8 inch collar. Try to test damper From zone control every time I try to open the damper it would open halfway and stick zone damper. Also zone damper actuator is making an Also zone damper actuator is making a buzzing sound. This is not normal. Sound Actuator should be replaced. I disconnected the two wires and forced the damper open so all areas of the house will get air
Found auxiliary drain pan full and condensate pump powered but not working - replaced condensate pump - removed water - cleared and treated drain line - cycled system to check operation. Found system about a pound low on r410a refrigerant charged to manufacturers specifications and checked unit operation - everything looks and runs great! Fixed bent Schrader on true suction line by replacing Schrader core.