Found system compressor windings appear to be shorted together W to U .3 ohms U to V .5 ohms V to W: 0.1 ohms System power and P.c. control board is also bad and should be replaced
Performed cooling tune ups on heat pump systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drains. Upstairs heat pump filter 20x20x4 is ready for replacement. Find filters easily at filterfetch.com using product code CKT-P4NY
Replace dehumidifier in attic tested operation
Found system coil dripping into blower compartment without ever touching the drain pan - adjusted blower speed - cleaned coil - pressed out moisture from unit insulation and wiped up water - cycled unit to check operation and waited for water to start dripping from the top of coil.
Mitsubishi system was not allowing system to ramp up fully due to attic unit reserving refrigerant from the branch box - after fully turning off attic guest wing unit and cycling system everything came on normally and returned to normal temperature differentials - cycled all zones to ensure proper system operation - adjusted system supply vents to achieve better flow across the basement.
Found upstairs attic unit indoor control board is receiving full communications and power from branch box and outdoor units but will no longer come on after a reset - discovered indoor communications board is not supplying voltage upon call for cooling - recommend replacement of indoor communications board - will call with availability.
Found attic air handler behind bookcase - powered on and calling for cooling but not doing anything. Checked air handler boards and thermostat IEM and found no faults - powered system completely down from outdoor unit circuit breaker - verified unit addressing correctly both inside and out - reset system power - flipped battery in outdoor temperature sensor - cycled indoor units from all thermostats - cycled attic unit several times to ensure unit properly turns off and on every time the thermostat calls for cooling. Everything appears to run normally again.
Performed cooling tune up service on Daikin minisplit system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor units, treatment of drains. Everything runs normally at this time.
Believe leak was caused by dirty filter causing indoor coil to freeze/thaw making unit coil over fill drain pan before float switch could cut off outdoor unit. System operates normally with new filter - checked system drain line - clear - added some algae tablets to drain pan
Performing a detailed AC repair today on a system short cycling every few minutes. Found the thermostat located too close to a supply vent, causing rapid cycling. Relocating the stat to a central hallway and adjusting anticipator settings to reduce swing. Also verifying correct system charge and airflow.
Installing a time-release treatment in the evaporator drain pan today. This type of treatment activates when it comes into contact with water and slowly releases EPA-registered antimicrobial agents. It helps prevent biofilm buildup, algae growth, and musty odors—great for keeping the drain line clear and the system running smoothly all season.
Working on a mini split maintenance for a 3-zone system. Cleaning filters, checking coil temps with an IR gun, and verifying proper expansion valve function. System is running clean and within the correct pressure range.
Changing out a clogged AC filter today. The customer had a 3-month-old filter completely covered in pet hair and dust. Educated them on monthly inspections during peak season and offered tips on better indoor filtration.
I’m troubleshooting a no-cooling issue. Outdoor unit is running but indoor blower isn’t. Found the ECM motor has failed—testing confirmed no rotation despite proper 24V signal. Ordering a replacement module and installing a surge protector to protect future electronics.
Found system receives power but not supplying 24 volts to board - replaced furnace 120 - 24v transformer and cycled system to check operation. Everything started up and ran normally!