253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Local Reviews
for fairview, nc

Rated 5.0 out of 5 stars based on 11 customer reviews

Excellent customer service at all levels.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Company!

I am quite fortunate to have Comfort Central as my HVAC company. They know their stuff arrive on time are very professional. I trust them to do a great job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Cameron and Jay were a great team to get our heat working again on a day where the outdoor temp was 22 degrees. Thank you.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

cameron has been very helpful and informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Reliable

Friendly and efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent company with exceptional customer service

I have been dealing with Comfort Central for many years. They do excellent work they show up on time I trust them to take care of all of my HVAC needs. they may be more expensive than other companies, but you get what you pay for.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Comfort Central provides great service.

Comfort Central is an excellent company. They have provided expert maintenance on the mini split system we purchased from them.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick appointment n service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fairview, nc

Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Check dehumidifier didn’t find anything wrong with it. Working good


Jay E.

Jay E. Job Checkin

SEER2 20, HSPF2 9.7, EER2 12.7 Make: Mitsubishi Model: MXZ-2C20NA4U1 2 Zone Outdoor Unit (2) MSZ-GL09NAU2 Indoor Units Installation shall include: Equipment specified above plus materials and labor to include: • Line voltage electrical reconnection is included. • Indoor units will be moved from above the center of the window to the left side of the window. • Refrigerant lines, electric cable from outdoor units to the indoor units, and drains will be replaced. • Permit Fee for Installation. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Mitsubishi Manufacturer’s Warranty: Twelve (12) Year Limited Parts, including Compressor. • One (1) Year Labor Warranty Provided by Comfort Central, Inc.


Cameron  S.

Cameron S. Job Checkin

Performed cooling tune ups on all minisplit systems checking all electrical components, refrigerant balance, unit start up, operations, shutdown, cleaning of indoor and outdoor units, filters, and drains. Checked dehumidifier operations, filters, and drains. Everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

Found outdoor p.c. Board was misaddressed causing unit to reserve refrigerant for 22 indoor units. After going through dip switch settings for indoor and outdoor units and correcting the error everything came on normally and cycles per manufacturers specifications.


Cameron  S.

Cameron S. Job Checkin

Performed hard reset on both indoor and outdoor units and cycling each unit individually and together to check operation. Everything comes on and cycled normally. System was not staging up blower speed on air handler but after a hard reset system blower is now speeding up normally and providing the proper temperature rise for system to heat properly.


Kelsey T.

Kelsey T. Job Checkin

Found breaker to outdoor unit turned off. Turned breaker on and tested system operation. Compressor is pulling 5 amps condenser fan motor is pulling 1.3 amps Heat pump temperature difference is 18 System is working to manufacturer specifications


Kelsey T.

Kelsey T. Job Checkin

serviced and inspected heat pump system, including electrical, safeties, controls, reversing valve and defrost cycle to manufacturer specifications. Heat strip is pulling 38 amps Blower is pulling .7 amps Temperature difference of heat strip is 24 Temperature difference of heat pump is 29.6 Compressor is pulling 9.5 amps Condenser fan motor is pulling 1.2 amps Defrost is working to manufacturer specifications


Cameron  S.

Cameron S. Job Checkin

Power board is not putting up power to the front board talk to Tech support. They want us to replace the power board and then see if the control board is bad as well. When we replaced the power board, we will be checking all the wires in that area to verify that they weren’t chewed on by the rodent. Replaced power board and checked all wiring inside outdoor unit. Everything started up and ran normally!


Cameron  S.

Cameron S. Job Checkin

System came on normally upon arrival - found outdoor temperature sensor trapped in discharge tube insulation moved sensor - cleaned flame sensor - blew out drains - cycled to check operation several times. Everything appears to work normally.


Andrew S.

Andrew S. Job Checkin

Serviced a commercial heat pump system, checking refrigerant levels, calibrating the thermostat, and cleaning coils for optimal performance.


Cameron  S.

Cameron S. Job Checkin

Performed tune up service on 3 gas furnace systems checking all electrical components, performed full combustion analysis, checked CO, CO2, Flue gas temperature, O2, and gas pressure. Checked systems start up, light off, shutdown, cleaned burners and flame sensors. Replaced downstairs hot surface ignitor. Everything looks and runs great!


Cameron  S.

Cameron S. Job Checkin

Found system locked out due to differing mode settings - changed all units into the same mode and cycled to check operation. Everything appears to be running normally again.


Cameron  S.

Cameron S. Job Checkin

Performed heating maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, defrost, shutdown. Everything looks and runs great!


Jay E.

Jay E. Job Checkin

We replace batteries on tune up. Terminal of where batteries go had a lot of corrosion on it. I removed metal piece and was able to get the corrosion off with sand paper. Now that contacts are clean the thermostat is powered. If the scene goes blank then we should replace tstat. Furnace only


Jay E.

Jay E. Job Checkin

AHRI# 207679247 28.4 SEER2; 15.4 EER2; 10.2 HSPF2 MAKE: Mitsubishi MODEL: MUZ-GS09NAHZ-U1 Outdoor Unit MSZ-GS09NAU1 Indoor Unit Pad for outdoor unit Installation shall include: Equipment specified above plus materials and labor to include: • Outdoor unit will be located in the front of the house and mount on the wall in the bedroom, blowing toward the door into the hallway. • Permit Fee for Installation • Line voltage electrical is not included and will be by others. • Mitsubishi Manufacture’s Warranty: Twelve (12) Year Limited Parts including Compressor. • First year Comfort Club is included. • One (1) year labor warranty provided by Comfort Central, Inc. • Ten (10) Year Guarantee on Comfort Central Inc Workmanship. Ultimate Heating Tune-Up Gas Heat: serviced and inspected gas heating system checking air flow, temperature rise, electrical, gas pressure, safeties, controls and limits, heat exchanger and venting. cleaned and checked system components to m