253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Local Reviews
for fairview, nc

Rated 5.0 out of 5 stars based on 7 customer reviews

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

cameron has been very helpful and informative.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Reliable

Friendly and efficient

  • Overall Experience
  • Quality
  • Price
  • Convenience

excellent company with exceptional customer service

I have been dealing with Comfort Central for many years. They do excellent work they show up on time I trust them to take care of all of my HVAC needs. they may be more expensive than other companies, but you get what you pay for.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Comfort Central provides great service.

Comfort Central is an excellent company. They have provided expert maintenance on the mini split system we purchased from them.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick appointment n service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for fairview, nc

Jay E.

Jay E. Job Checkin

Remote sensor batteries in guest bedroom Are bad Replaced them and made sure it was communicating to tstat


Kelsey T.

Kelsey T. Job Checkin

Delivery person told homeowner it was cold in garage apartment. On arrival system is blowing hot air as intended. Conclusion: delivery driver mistook defrost cycle as a malfunctioning unit.


Kelsey T.

Kelsey T. Job Checkin

Delta T of 23-25 on all power heads. Treated all coils indoor and outdoor with green coil cleaner. No signs of over-amping from outdoor unit. Blowers are all clean from the previous pull and clean visit. Filters have very light dust. No signs of water leakage from any of the power heads. Defrost functioning normally. System is heating normally.


Kelsey T.

Kelsey T. Job Checkin

Delta T of 33. Filter changed. Drain trap brushed out. Checked coils, blowers, amps, temps, and pressures. Treated outdoor coil with coil cleaner. Instructed homeowner on using the automatic setting on her upstairs thermostat. Patched test hole. Tested heat strip. System is functioning normally.


Kelsey T.

Kelsey T. Job Checkin

Need to return.


Cameron  S.

Cameron S. Job Checkin

Performed ultimate heating tune up checking all furnace components, performed full combustion analysis, cleaned burned and flame sensor, checked all electrical, checked furnace start up, operation, shut down, exercised safeties to insure proper unit operation. Everything looks and runs great! No recommended changes at this time.


Cameron  S.

Cameron S. Job Checkin

Thermostat subbase was convex on wall causing thermostat to disconnect from EIM and shut off dehumidifier. Reseated subbase, shimmed behind it and made sure sits flat against the wall. Adjusted dehumidifier to make sure runs efficiently - system achieved 45% humidity in 15 minutes. Flushed drains cleaned float switches to insure no drainage issues. Everything else looks and runs great! Covered under workmanship and satisfaction guarantee.


Kelsey T.

Kelsey T. Job Checkin

Delta T of 16. Subcool of 11. Superheat of 3. Filter needs to be replaced. Blew out trap to condensate pump. Treated outdoor coil with cleaner. System is old (r22). Recommended new unit. Homeowner requested estimate.


Cameron  S.

Cameron S. Job Checkin

Performed 3 ac tune up services checking all electrical components, refrigerant balance, unit start up, operation, shut down. Cleaning of indoor and outdoor coils and drains. Everything looks and runs great no recommended changes at this time.


Cameron  S.

Cameron S. Job Checkin

Recommend replacement of right side of house system. Will return to give an estimate to replace system.


Jay E.

Jay E. Job Checkin

Ac tuneup. I think The rattling noise was coming from a register. I made an adjustment to it started and stopped the unit three times I couldn’t hear another rattle.


Jay E.

Jay E. Job Checkin

Tune up on all heads, air handlers and out door units . No issues Dehumidifier in art room was not working. Cycled off and on. System started working. Call tech-support they recommend we replace the internal board and user interface board. They estimate 10 days until parts arrive.Being that there was a call for Dehumidification in the master bedroom And the dehumidifier was not working. The air handler blower was still running. This would cause over cooling and humidity being that if another Device on that system was running would make the coil in the original air handler cold and wet from condensation. Once the dehumidifier parts are changed the warm air that comes out of the dehumidifier will warm the air going across the cold coil therefore no longer getting over cold and it will remove the humidity on that coil as it runs.


Cameron  S.

Cameron S. Job Checkin

Found attic system drain had backed up causing unit float switch to trigger to turn system off. System working upon arrival because emergency drain pan had lost enough water to allow unit to come on. Checked operation of system. Removed drain blockage. Sold 3 tune ups for August 17th 10am time slot.


Cameron  S.

Cameron S. Job Checkin

Deep Cleaning of (4) Indoor Power Heads and Replacement of PC Communication Board in outdoor unit. Will return with 2 indoor power boards for right side Mitsubishis


Jay E.

Jay E. Job Checkin

AC NO COOL - MITSUBISHI UNIT No power At thermostats of zones.. found the moisture sensor in emergency drain pan to be tripped causing a lockout. Reset switch tested operation. Did not find any type of moisture in drain pan. It’s possible the water sensor switch could be going bad if this happens again I recommend we replace the switch