Performing a detailed AC repair today on a system short cycling every few minutes. Found the thermostat located too close to a supply vent, causing rapid cycling. Relocating the stat to a central hallway and adjusting anticipator settings to reduce swing. Also verifying correct system charge and airflow.
Installing a time-release treatment in the evaporator drain pan today. This type of treatment activates when it comes into contact with water and slowly releases EPA-registered antimicrobial agents. It helps prevent biofilm buildup, algae growth, and musty odors—great for keeping the drain line clear and the system running smoothly all season.
Working on a mini split maintenance for a 3-zone system. Cleaning filters, checking coil temps with an IR gun, and verifying proper expansion valve function. System is running clean and within the correct pressure range.
Changing out a clogged AC filter today. The customer had a 3-month-old filter completely covered in pet hair and dust. Educated them on monthly inspections during peak season and offered tips on better indoor filtration.
I’m troubleshooting a no-cooling issue. Outdoor unit is running but indoor blower isn’t. Found the ECM motor has failed—testing confirmed no rotation despite proper 24V signal. Ordering a replacement module and installing a surge protector to protect future electronics.
Found system receives power but not supplying 24 volts to board - replaced furnace 120 - 24v transformer and cycled system to check operation. Everything started up and ran normally!
Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Check dehumidifier didn’t find anything wrong with it. Working good
SEER2 20, HSPF2 9.7, EER2 12.7 Make: Mitsubishi Model: MXZ-2C20NA4U1 2 Zone Outdoor Unit (2) MSZ-GL09NAU2 Indoor Units Installation shall include: Equipment specified above plus materials and labor to include: • Line voltage electrical reconnection is included. • Indoor units will be moved from above the center of the window to the left side of the window. • Refrigerant lines, electric cable from outdoor units to the indoor units, and drains will be replaced. • Permit Fee for Installation. • All work will be completed in a professional workmanlike manner. • Old equipment and trash from installation will be removed from premises. • Mitsubishi Manufacturer’s Warranty: Twelve (12) Year Limited Parts, including Compressor. • One (1) Year Labor Warranty Provided by Comfort Central, Inc.
Performed cooling tune ups on all minisplit systems checking all electrical components, refrigerant balance, unit start up, operations, shutdown, cleaning of indoor and outdoor units, filters, and drains. Checked dehumidifier operations, filters, and drains. Everything looks and runs great!
Found outdoor p.c. Board was misaddressed causing unit to reserve refrigerant for 22 indoor units. After going through dip switch settings for indoor and outdoor units and correcting the error everything came on normally and cycles per manufacturers specifications.
Performed hard reset on both indoor and outdoor units and cycling each unit individually and together to check operation. Everything comes on and cycled normally. System was not staging up blower speed on air handler but after a hard reset system blower is now speeding up normally and providing the proper temperature rise for system to heat properly.
Found breaker to outdoor unit turned off. Turned breaker on and tested system operation. Compressor is pulling 5 amps condenser fan motor is pulling 1.3 amps Heat pump temperature difference is 18 System is working to manufacturer specifications
serviced and inspected heat pump system, including electrical, safeties, controls, reversing valve and defrost cycle to manufacturer specifications. Heat strip is pulling 38 amps Blower is pulling .7 amps Temperature difference of heat strip is 24 Temperature difference of heat pump is 29.6 Compressor is pulling 9.5 amps Condenser fan motor is pulling 1.2 amps Defrost is working to manufacturer specifications
Power board is not putting up power to the front board talk to Tech support. They want us to replace the power board and then see if the control board is bad as well. When we replaced the power board, we will be checking all the wires in that area to verify that they weren’t chewed on by the rodent. Replaced power board and checked all wiring inside outdoor unit. Everything started up and ran normally!
System came on normally upon arrival - found outdoor temperature sensor trapped in discharge tube insulation moved sensor - cleaned flame sensor - blew out drains - cycled to check operation several times. Everything appears to work normally.