Cameron was in and out on a Saturday morning that was appreciated. He always keeps us informed on each step in the process.
Cameron was early and let us know and completed work quickly.
We were without heat heading into the holiday weekend and reached out to Comfort Central on Friday afternoon. They had us scheduled for following morning at 8:00. Cameron was prompt and quickly diagnosed the problem. He was able to repair our heat pump and update the software. We had heat for our family at Christmas!
Our need to have a warm home for Christmas guest was answered above and beyond by Comfort Central. The service technician, Cameron, was thorough and diligent in correcting wiring problems and updating our equipment with the latest software updates. He’s a genius. Planning to switch from our current service provider to Comfort Central.
Kevin, Jay, and the team at Comfort Central met and exceeded our expectations with the design and installation of our new HVAC system and whole house dehumidifier. The process was efficient and the team always arrived on time, exactly when they said they would. Jay took time to explain the details of the new system and answered each question with professional care and concern. I would highly recommend Comfort Central.
I was once again impressed with the technical competence of a representative of Comfort Central. Jay did not assume anything about the problem at hand but systematically and thoroughly analyzed and solved it. Customer service, high quality level and consistency of performance set this company apart from any competitor in the area of air conditioner and heating service.
Found system 1.5 lbs low on r410a causing it to kick out in low pressure during low outdoor temps. Charged with refrigerant and cycled to check operation. Recommended we return in the spring to check refrigerant balance and perform a leak search on system.
Performed heating maintenance tune up service on dual fuel system checking all electrical components, refrigerant balance, unit start up, operation, defrost, shutdown. Cleaning of burners, flame sensor, drain. Everything looks and runs great!
Found fuse corroded causing system not to supply power to thermostat replaced fuse and cycled system in both heat and cool.
Found system 2.5 lbs low on refrigerant added 2.5 lbs r410a refrigerant to system and checked for leaks found high side Schrader core slightly out leaking slightly - righted Schrader and stopped leak. Cycled system to check operation. Everything runs normally again!
Performed AC maintenance tune up service on straight AC systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils l, treatment of drain lines, and checking of filters.
Performed AC maintenance tune up service on single power head Mitsubishi system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils and treatment of the drain. Reset thermostat and shut off lights locked up house according to customer instructions. Everything is good to go for the summer!
Performed AC maintenance tune up service on AC/Heatpump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain line. Everything looks and runs great!
Found both units a little low on refrigerant added 1 lb r410a to main and 1 lb r410a to upstairs unit. After adding refrigerant noted main system txv slammed shut. Recommend replacement of TXV (thermostatic expansion valve) will call with quote.
Found thermostat programmed and wired for conventional forced air furnace when dual fuel system was installed. Reprogrammed and rewired thermostat for dual fuel operation. Removed a stick wedged between outdoor fan blade and unit shroud causing heat pump condenser fan motor not to come on. Cycled unit in all heating stages to check operation of unit. Found system required software update via comfort cloud app updated software and reconfigured system. Everything runs normally at this time.
Replaced 45 amp breaker with a 50 amp breaker
14.3 SEER 2; 7.5 HSPF 2 Make: Goodman Model: GSZB402410A Heat Pump AMST24BU14 Fan Coil 8 KW Electric Heat Honeywell T-6 Thermostat Tech Pure Merv 11 Media Filter Installation shall include: Equipment specified above plus materials and labor to include: • All work will be completed in a professional workmanlike manner. • Goodman Factory Warranty: Ten (10) Years Limited Parts. • Honeywell warranty: 5 Years parts. • Line voltage electrical is included. • One (1) Year Labor Warranty Provided by Comfort Central, Inc. • Ten (10) Year Guarantee on Comfort Central, Inc. Workmanship. • 100% Customer Satisfaction Guarantee for the first year
R22 system. Almost no refrigerant in system. Set up estimate for 9/20 at noon.
Performed AC tune ups on 3 minisplit power heads (2 condensers) checking electrical, refrigerant balance, cleaning of indoor and outdoor units, cleaning of filters, checking operation including start up and shut down. All 3 units running within manufacturers specifications bedroom and kitchen units had 25° temperature drop and outdoor kitchen area had 23° temperature drop indicating all units working in top performance.
Performed AC cooling tune up on Trane minisplit system checking all electrical components, refrigerant balance, unit start up, operation, shut down. Cleaning of indoor and outdoor coils. Cleaning of filters and flushed drains. Everything looks and runs great! Temperature differential of 20°F. Blower Amps 0.5, compressor 2.4, outdoor fan 0.5. No recommended changes at this time.