253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Local Reviews
for hendersonville, nc

Rated 5.0 out of 5 stars based on 48 customer reviews

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

Cameron did a great job. He was very thorough and gave me an explanation of his inspection.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Wonderful customer service

Getting a new HVAC system is not a fun purchase, but the people at Comfort Central made it easier. From the phone call with Laurie in the office to set up the appt. to Kevin coming out to do the estimate to the technicians, Jay, Cameron, and Zach all of them exhibited great customer service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

The technician went above and beyond to fix the problem with my heater, which was actually an electrical issue

  • Overall Experience
  • Quality
  • Price
  • Convenience

great service

Cameron did a fantastic job analyzing and repairing the problem with our hvac unit. Very professional and knowledgeable. We will definitely use his service again.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent, Efficient, Professional

We have worked with several members of the Comfort Central staff and have found them all to be knowledgeable, professional and dependable. An excellent organization!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Consistently satisfaction

Technician (Jay) arrived on time. He determined the reason for our problem, and resolved it within a reasonable amount of time. Comfort Central stands behind their service and aims for 100% satisfaction. I have utilized their services for 5+ years and have always been pleased with the outcome.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Always on time, friendly, knowledgeable

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

Cameron was great (as usual). He is very personable and always does a thorough job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Continued excellence!

Thomas provided thorough and efficient service again in repairing some duct work that needed replacing after the storm. Kelsey from the office was also great in communicating timelines and availability for the work. Comfort Central sets the bar for excellence in service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Continued excellence!

Cameron diagnosed and repaired our problem quickly and professionally. Clear communication and thorough work. Always a pleasure dealing with Comfort Central!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Seeds to know what he is doing I would recomend him to any one

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent and prompt service!

Comfort Central has always provided excellent service and this time has been no exception. Thomas has been a pleasure to work with. Prompt service. Very knowledgeable and able to answer and explain all of my questions clearly.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great annual maintenance

Team continues to provide good service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for hendersonville, nc

Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications Everything is running as designed no issues found


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on heat pump system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drains and condensate pump.


Cameron  S.

Cameron S. Job Checkin

Performed cooling tune up service on AC system checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain and condensate pump. Everything looks and runs great!


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Found a bad capacitor on heat pump must be replaced.


Cameron  S.

Cameron S. Job Checkin

Performed AC cooling tune up service checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain line. Everything looks and runs great!


Jay E.

Jay E. Job Checkin

Furnish materials and labor for replacement of OEM Defrost Board, covered under manufacturer parts warranty. Includes warranty processing. Had to call Tech Support because the core sense diagnostic device was saying that it was locked out unlocked rotor amps. I pushed the contactor in the compressor is only pulling 6 A. The core sense wouldn’t reset Tech Support recommends. We replace the core sense diagnostic device.


Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

Found fuse to be open. Put little Popper breaker where the fuse goes. Tested all operation to see if I could get the fuse to pop again. found the outdoor unit not coming on. Said had an 05 fault which was the board. Reset everything try to make it start. I had 24 V coming into the board check high pressure low pressure. Both safeties were closed. Then I started getting a low pressure fault. So I put jumpers across it. Still got default. Try to reset the fault it was stuck. Defrost board needs to be replaced.


Jay E.

Jay E. Job Checkin

Communicating system. Was told that thermostat said wait and the system wouldn’t come out of wait. To turn on the AC. When I arrived, I turned system on everything came on drain trap was kind of dirty so it’s there’s a possibility that the float which triggered the issue. We started and stopped the unit several times and ran it for a while with no other issues. If this happens again now that the drain is clear, we may have to call Tech Support and have them help us figure out what’s going on. Temperature difference was 20° Also noticed that the return air duct was vibrating, causing a humming noise. Went ahead and checked static pressure on the system and for 4 ton unit I believe the ducks are too small to carry the air as the filter is clean. The system has .9 static pressure. This can cause blower motor issues and compressor issues. But this has nothing to do with what’s going on today.


Andrew S.

Andrew S. Job Checkin

I’m servicing a mini split head unit that isn’t cooling properly. Found the blower wheel coated with dust, restricting airflow. Removing the housing, cleaning the wheel with coil-safe solution, and checking the thermistor for accurate feedback.


Jay E.

Jay E. Job Checkin

Installing a whole-home dehumidifier in a damp basement. The model integrates with existing ductwork and includes a dedicated return for humidity control. It features a built-in hygrometer, low-temp operation, and an external condensate pump for reliable drainage. Wiring it to an independent circuit and programming it for 50% RH setpoint.


Cameron  S.

Cameron S. Job Checkin

Replacing an AC contactor today. Unit failed to start and the contactor showed pitting and carbon buildup. Swapping in a new 2-pole contactor and confirming proper voltage and amperage draw across L1/L2 terminals.


Kevin S.

Kevin S. Job Checkin

Investigating an AC system with a strange smell. The odor is coming from microbial buildup in the evaporator coil and drain pan. Using a non-corrosive disinfectant and installing a Pure AirX time-release treatment to suppress future biological growth. Discussing UV light options with the customer for long-term IAQ control.