253 Timberlane Dr
Pisgah Forest, NC 28768
828-483-4040

Local Reviews
for pisgah forest, nc

Rated 5.0 out of 5 stars based on 25 customer reviews

Excellent Service!

Life saver! Really appreciate the help.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding service!

Everyone I came into contact with on this project were very patient and understanding with my many questions and extremely professional. They worked very diligently with the installation and it ran flawlessly. Jay also took time to give me suggestions on how I could continue to make my home more energy efficient.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, very convenient. Thorough technician.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Happy Customer

Cameron was polite, helpful, knowledgeable,

  • Overall Experience
  • Quality
  • Price
  • Convenience

Experienced service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service without question

Kept me informed of what they were doing and why. They explained everything in detail so that I could understand.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

Cameron was very courteous and knowledgeable. Very good at diagnosing and explaining technical procedures.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Amazing service

Educational, spoke to me in a way that I could understand, present, great communication. Helped me save on future services.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent service!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Both men were professional and courteous

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent & Friendly Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work

Thorough and efficient. Cleaned up after. Friendly and easy to work with.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Experts in HVAC

There was a modification I wanted done to integrate the humidifier. The controller was not standard, but they persisted until it was operating as desired. We signed up for the Comfort Club!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent Service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very knowledgeable and thorough

Every option was explored in terms of repairs, installs, and pricing. Work was double checked and was thorough. Highly recommend for their experience and know how along with overall honesty and understanding of the situation.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pisgah forest, nc

Kelsey T.

Kelsey T. Job Checkin

Performed maintenance on heat pump Temperature difference between return and supply is 20 Blower is pulling.6 amps Compressor is pulling 3 amps Outdoor fan motor is pulling 1.3 amps Subcool is 8 superheat is 12 Capacitor is within manufacturer specifications Cleaned indoor and outdoor coils Cleared condensate line System is working great


Kelsey T.

Kelsey T. Job Checkin

Found drain pan leaking water, drain pan will need to be replaced. Customer also wants an estimate for replacement of system. Scheduled for Friday at 8.


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on heat pump systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain lines and condensate pumps, cleaning of dehumidifier filter.


Cameron  S.

Cameron S. Job Checkin

Found contactor for main system had blown apart - replaced contactor and cycled system to check operation. Everything came on normally. Found capacitor for upstairs system out of range and caused system to not come on normally. Replaced capacitor and cycled to check operation. Everything came on normally as well. No other recommended changes at this time. Could take a few hours for system to cool house to temp but refrigerant balance is good on both systems and rest of electrical components work great!


Cameron  S.

Cameron S. Job Checkin

AC systems have only 120v out of 240 volts going to them indicating that a leg of 120 has dropped off from service. Recommended an electrician come and restore power. Told to call schedule a service when system power is restored. Waived today's diagnostic fee.


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on Bosch heat pump system checking all electrical, components, refrigerant balance, unit start up, operation, shutdown, cleaning of my indoor and outdoor coils, flushing and treatment of drain line and condensate pump. Everything looks and runs great!


Jay E.

Jay E. Job Checkin

Perform tuneup found hard start kit not working probably causing the compressor not to start. We’ll go ahead and order one of those and also an air purifier Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications.


Jay E.

Jay E. Job Checkin

MAKE: Goodman MODEL: GSZB403010 Heat Pump CHPTA3026B4 Evaporator Coil Honeywell Prestige IAQ Thermostat Installation shall include: Equipment specified above plus materials and labor to include: • Necessary Electrical for Installation. • Permit Fee for Installation • Goodman Manufacture’s Warranty: Ten (10) Year Limited Parts including Compressor. • One (1) year labor warranty provided by Comfort Central, Inc. • Ten (10) Year Guarantee on Comfort Central Inc Workmanship.


Jay E.

Jay E. Job Checkin

Pulled power head off of bracket and screwed drywall off to newly added stud. System is now secured to wall


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up on minisplit systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils and drains. Set up appointment to remount new minisplit power head in basement for Tuesday July 2nd around 2 pm.


Cameron  S.

Cameron S. Job Checkin

Adjusted speed tap of blower motor to speed 4 med-high. Adjusted system charge added 8 oz r410a to bring sub cooling from 1 to 8 and super heat from 3 to 8. System now has a 19.5 temperature split up from 17. System blower amps 1.2 compressor amps 5.4 outdoor fan motor .9. system static pressure went down from .75 to .47. System thermostat satisfied at 74 and system shuts off normally.


Cameron  S.

Cameron S. Job Checkin

Found system reading 02 fault. 02 fault reading high pressure fault - reset fault on outdoor board by removing R wire from board for 1 minute then reconnected. After system reset system came on under normal conditions highest pressure was 285.3 psi with a cut off at 400 psi. Recommend if system fails again to reset from breaker panel shutting off both indoor and outdoor unit breakers four about a minute and waiting for the time delay to bring unit back on. Issue could be caused by an intermittent board failure or sensor failure but both reading normally at this time. Covered as family.


Kelsey T.

Kelsey T. Job Checkin

When I arrived system was turned off. Turned system on and found capacitor on outdoor unit was bad, and filter at unit was clogged. Replaced capacitor and removed filter, then tested system operation. System is now working correctly. Superheat was 10 subcool was 6. Temperature difference between return and supply was 22. The clogged filter was restricting air flow across the coil and most likely the reason the system iced up.


Jay E.

Jay E. Job Checkin

AHRI# 213368081 15.2 SEER2; 12.5 EER2; 7.5 HSPF2 MAKE: Goodman MODEL: GSZB401810 Heat Pump AMST24BU1400BA Air Handler 3 KW Electric heat kit Tech Pure TTMAC 1722 Merv 11 media filter Honeywell T-6 Thermostat Installation shall include: Equipment specified above plus materials and labor to include: • Necessary Electrical for Installation. • We will add a base box and add a return air duct through the wall at the top of the stairs. A flexible connector will be added between base box and return to isolate vibration. • We will replace (2) 6” x 10” supply grills in bedroom with high efficiency grills. • Permit Fee for Installation • Goodman Manufacture’s Warranty: Ten (10) Year Limited Parts including Compressor. • One (1) year labor warranty provided by Comfort Central, Inc. • Ten (10) Year Guarantee on Comfort Central Inc Workmanship.


Cameron  S.

Cameron S. Job Checkin

Performed AC maintenance tune up service on both heat pump systems checking all electrical components, refrigerant balance, unit start up, operation, shutdown, cleaning of indoor and outdoor coils, treatment of drain lines and condensate pumps. Everything looks and runs great!