serviced and inspected heat pump system, including electrical, safeties, controls, reversing valve and defrost cycle to manufacturer specifications. Outdoor temperature is 56 Blower motor is pulling 1.3 amps Heat strips are pulling 31.1 amps Heat strip temperature difference is 31 Compressor is pulling 6.1 Amps Condenser fan motor is pulling 1.4 amps Heat pump temperature difference is 34 Capacitor is within manufacturer specifications Defrost is working to manufacturer specifications System is working great!