Jay E.

Jay E. Job Checkin

Ultimate Cooling Tune-Up: cleaned coils, brushed and cleaned traps, added pan treatment tablets to pan. tested and checked all controls, wiring connections. tested temperatures, checked filters. checked refrigerant temperature and pressures, tested static duct pressure. tested blower operation, tested cooling operation to ensure working within manufacturer specifications. Found system to utilize refrigerant R22 that’s no longer manufacture and parts Are no longer manufactured. Found system to be severely low on this R22 refrigerant. Found system functioning with a 4° temperature difference. Normal temperature difference is 18 to 22. Being that the pressure of the refrigerant is low, the temperature will be low causing the coil to freeze up. I recommend the system be replaced as it is almost 28 years old and will not cool.


Jay E.

Jay E. Job Checkin

Ground fault outlet tripped that the condensation pump is plugged into. Reset gfi . System started no issues. Pump worked no issues. If this happens again we may have to replace gfi and or pump


Cameron  S.

Cameron S. Job Checkin

Unit was sagging on its rack adjusted seating of unit and checked operation stopped dripping past the drain pan. Pulled vac on all 3 drain pipes outside to ensure flow.


Jay E.

Jay E. Job Checkin

2 heat pump tuneups on York and ADP systems found system low on 410a refrigerant. Tested a/c and heat operation


Jay E.

Jay E. Job Checkin

Fixed a broken rheem air conditioner


Jay E.

Jay E. Job Checkin

Checking operational function a little Johnny come and see him on a Coleman


Jay E.

Jay E. Job Checkin

Changing a bad capacitor on a comfort maker air conditioner