Today I arrived on site and performed a winter time tune up on your system. Here's a summary of the work completed: **System Overview:** * Equipment condition assessed as fair. * Indoor unit is an air handler located in a closet within the crawl space. * Outdoor unit is a heat pump located on the side of the house. * The unit services the whole home. **Component Inspections & Testing:** * Checked the pleated 1" filter. * Verified the blower motor, heat strip kit, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring are working within manufacturer specifications. * Observed the blower wheel, secured electrical wires, primary drain pan, and secondary drain pan are in good condition and working properly. * Confirmed the drain line is strapped. **Measurements & Adjustments:** * Measured a return air temperature of 69.0°F and a supply air temperature of 109.0°F. * Cleared the condensate drain line and cleane