5402 Tower Rd
Tallahassee, FL 32303
850-562-3132

Job Locations
for madison, fl


Map of Madison FL
Bryce D.

Bryce D.


Job Checkin

Today, I arrived on site to perform a thorough inspection and maintenance of the HVAC system. Equipment Condition: * Overall condition rated as fair. * Indoor unit located in the attic; type is air handler. * Serves the whole home with a washable filter that was cleaned today. * Filter size measured at 16x20x5. Indoor Coil: * Condition is fair and clean. Outdoor Unit: * Located on the side of the house; type is heat pump. * Outdoor coil condition is also fair and clean. Electrical Components: * Blower motor, condenser fan motor, compressor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring tested and are functioning within the manufacturer's recommended specifications. Inspected Components: * Blower wheel, primary drain pan, and electrical wires are secured and in good condition. Temperature Readings: * Return air temperature recorded at 77.0 degrees Fahrenheit. * Supply air temperature measured at 60.9 degrees Fahrenheit. Condensate Drain System: * C