Today I arrived on site and performed a summer tune-up on your system. Here’s a summary of the work completed: System Overview: Overall equipment condition: Good. Unit services: Whole home. Indoor Unit (Air Handler in Closet): Filter: Replaced the pleated 1" filter (24x24x1). Indoor coil condition: Good. Outdoor Unit (Heat Pump in Back Yard): Outdoor coil condition: Good. Electrical Components: Tested and inspected: Blower motor, condenser fan motor, compressor, blower run capacitor, compressor run capacitor, fan run capacitor, contactor, and electrical wiring – all operating within manufacturer specifications. System Components (Inspected and in Good Condition): Blower wheel, secondary drain pan, primary drain pan, and electrical wires secured. Condensate Drain System: Cleared drain line. Cleaned out primary and secondary pans. Tested safety switch. Measurements: Return air temperature: 75.0°F. Supply air temperature: 55.0°F. Final Steps: Restored power to the units. Tested th